Monitoring and regulating equipment
Float switch in the recycled water tank
Floater switch in the pump basin
Immersion pump
Motor output
Voltage
Power consumption
Flow rate at approx. 0.1 MPa (1 bar)
Pressure
Entire unit
Filter capacity
Voltage
Frequency
Weight
Width
Depth
Height

Maintenance and care

Maintenance instructions

The bases of a safe operating of the equip-
ment is thr regularly maintenance accord-
ing to the following maintenance plan.
Use only original parts of the manufacturer
or part suggessted by him, such as
parts and wearing parts,
accessories parts,
operating materials,
cleaning agents.
Danger
Risk of accident while working on the unit.
During all tasks
Deenergize the system: Pull the mains
plug and secure the system against be-
ing switched back on.
Shut off water supply.
18
S7 up
Recycled water tank full. Filling process is stopped.
S7 down
Recycled water tank is filled.
S9 up
Switching off the fresh water supply. Indicator lamp "Fresh water supply active" goes off.
Illuminated lamp "Fresh water supply was active" lights up yellow.
S9 down
Switching on the fresh water supply. Indicator lamp "Fresh water supply active" and
"Fresh water supply was active" lights up yellow.
S11 up
Dry run protection for wash pump not active, no error message.
S11 down
Dry run protection for wash pump active, error message on the washing system.
S5 top
Pump basin overfilled. Starting the disposal via the recycling water tank into the chan-
nel
S5 bottom
Pump basin is not overfilled, normal system operation.
S4.1 top
Pump basin is not sufficiently filled, normal system operation.
S4.1 bottom
no function
S4.2 top
no function
S4.2 bottom
Pump basin empty, dry run protection of immersion pump active, no filtration, no back-
wash possible. System runs on fresh water.

Technical specifications

Who may perform maintenance?
Operator
Work designated with the sign "Opera-
tor" may only be carried out by persons
who have been instructed in the safe
operation and maintenance on washing
systems with recycling unit.
Customer Service
Work designated with the sign "Cus-
tomer Service" may only be done by the
fitters of Kärcher Customer Service.
Maintenance contract
In order to guarantee a reliable operation
og the equipment, we success, you signed
a maintenance agreement. Please refer to
you local Kärcher service department.
W
V
A
m
/h
3
MPa (bar)
m
/h
3
V
Hz
kg
mm
mm
mm
6
-
EN
WRP 10000
WRP 20000
1.217-130.0
1.217-140.0
1300
1700
230/1~
230/1~
5,9
8,5
approx. 10
approx. 20
max. 0.14 (1.4) max. 0.16 (1.6)
max. 10
max. 20
230/1~
230/1~
50
50
280
390
700
900
620
780
1600
1600