Selecting the Reference Level (see figure A)
For the measurement, you can select between four reference
planes:
– The rear edge of the measuring tool or the front edge of the
90° folded-out positioning pin 9 (e.g. when measuring on-
ward from outer corners),
– The tip of the 180° folded-out positioning pin 9 (e.g. when
measuring from a corner),
– The front measuring-tool edge (e.g. when measuring on-
ward from a table edge),
– The centre of thread 19 (e.g. for tripod measurements).
To select the reference level, press button 10 until the re-
quested reference level is indicated on the display. Each time
after switching on the measuring tool, the rear end of the
measuring tool is preset as the reference level.
Subsequent changing of the reference level for measure-
ments that have already been carried out (e.g. when indicat-
ing measuring values in the measured-value list) is not possi-
ble.
"Basic Settings"
To access the "Basic settings" menu, press and hold the basic
settings button 4.
Briefly press the basic settings button 4 to select the individ-
ual menu items.
Press the minus button 5 or the plus button 11 to select the
setting within the menu items.
To exit the "Basic settings" menu, press the measurement
button 2.
Basic Settings
Tone Signals
Display Illumination
Digital vial
Display rotation
2 609 140 807 | (11.5.11)
Basic Settings
Permanent laser beam
Unit of measure, distance
(depending on country ver-
sion)
Unit of measure, angle
With exception of the "Permanent laser beam" setting, all ba-
sic settings are retained when switching off.
Continuous Laser Beam
Do not point the laser beam at persons or animals and
do not look into the laser beam yourself, not even from
a large distance.
In this setting, the laser beam also remains switched on be-
tween measurements; for measuring, it is only required to
press the measuring button 2 once.
Measuring Functions
Simple Length Measurement
For length measurements, press button 12 until the "length
measurement" indication appears on the display.
On
ments, the last measured results are displayed in the meas-
ured-value lines a.
Off
Area Measurement
For area/surface measurements, press button 12 until the in-
On
dicator for area measurement
Afterwards, measure the length and the width, one after an-
Off
other, in the same manner as a length measurement. The laser
beam remains switched on between both measurements.
Auto on/off
On
Off
Volume Measurement
On
For volume measurements, press button 12 until the indica-
tor for volume measurement
Afterwards, measure the length, width and the height, one af-
Off
ter another, in the same manner as for a length measurement.
The laser beam remains switched on between all three meas-
urements.
On
Off
m, ft, inch, ...
°, %, mm/m
To switch the laser on and for measuring,
briefly press the measuring button 2 once
each time.
The measured value is displayed in the re-
sult line c.
For several subsequent length measure-
appears on the display.
Upon completion of the second measure-
ment, the surface is automatically calcu-
lated and displayed in the result line c.
The individual measured values are dis-
played in the measured-value lines a.
appears on the display.