1. UNPACKING AND INSPECTION: The following items should all be within the carton:
Item
Cap c/w rigid Impact-Liner
®
PowerCap
Active™ Drive Unit
1mm Polycarbonate Visor
0.35mm Polycarbonate Visor
PowerBox™ Battery Pack
PowerStation™ Charging Dock
Intelligent Li-Ion charger
Airflow Test Unit
Note: PowerCap
®
Active™ also provides protection to EN 812, the BumpCap standard.
It should be noted that the special liner for this protection forms an integral part of the cap structure. Ensure that the "HardCap A1+" liner is fitted into the Cap before use.
2. STORAGE: When not in use or during transportation, PowerCap
away from direct sunlight, not in contact with solvents and in such a manner that it cannot be damaged by physical contact with hard surfaces. Storage temperature should be
between 5°C and 40°C and relative humidity not greater than 75%. During storage, the PowerCable should be disconnected from the PowerBox™ battery pack.
3. BEFORE USE: PowerCap
®
Active™ uses JSP's PowerBox™ battery system. The batteries will come
supplied with some residual charge present. The unit should be run until the batteries are fully exhausted.
The battery has over discharge protection and will cut out when exhausted and then a full 16 hour charge
should be applied. An 8 hour (overnight) charge will produce 8 hours of run time from PowerCap
The charger socket is located on rear of the PowerStation™ charging dock.
The The Battery can be charged whilst still attached to the Cap.
The Battery can be charged whilst separated from the Cap.
Spare PowerBox™ batteries are available from JSP Ltd or its distributors.
Charging the batteries: On receipt of the unit, run the battery flat and charge for 16 hours to reach
maximum capacity. Follow on charging cycles should then take 8 hours. If the unit is run completely flat
or the unit has not been used for a long period it would be advisable to repeat the 8-16hr charge cycle. A
reduced charging time will reduce the time that PowerCap
transformer has an LED on it and the LED will show red while charging and green when fully charged. The
battery has over-charge protection and will not be damaged by being on charge for longer than 8 hours.
4. USING PowerCap
®
: Unit: The PowerCap
temperature should be between 5°C and 40°C and relative humidity not greater than 75%.
Filters: The filters provided are high efficiency sub-micron particulate types supplied in pairs. They will filter most particulate matter such as dust, spores, mist and fumes, but like
all filters cannot filter out all particulate matter present in the air. They will not filter gases, vapours or toxic substances.
The duration of filter life will depend mainly on the amount and size of the contamination in the area where they are used, and the time used in that area. Inspect the filters
regularly. Ensure that they are located correctly and carefully remove any visible large surface contamination to prolong their life. The filters must not be washed or allowed to
get wet. A low airflow reading (red section of indicator) usually indicates that new filters are required.
Fitting and replacing the filters: Only replace with a pair of genuine
replacement filters supplied in pairs from JSP Ltd or its distributors.
Filters are marked as per this example image:
Simply twist anticlockwise, with filter towards you, and lift away from
motor housing. Replacement is the reverse procedure. Ensure that
the filter and motor housing mating faces are clean; do not allow
any dust or foreign objects to fall into the motor housing.Push and
twist the replacements firmly into place. Recheck airflow when the
new filters have been fitted before use. If the filters are not fitted
correctly, filtering efficiency will be severely reduced.
Battery and Airflow Check: PowerCap
battery charge and airflow the filters must be fitted and the visor removed (see 'removing/fitting the visor').
a. Having removed the visor insert the male connector at the end of the PowerCap
the female connector on the PowerBox™ battery compartment.
b. Switch the unit on using the switch located on the PowerBox™ battery unit. Airflow will now commence. It is
now necessary to check that the airflow is sufficient, and the following checks should be carried out on a regular
basis with the filters fitted and always before use of PowerCap
b.1. Invert (turn upside down) the PowerCap
inside the rim of the Visor Carrier ensuring a good seal. Avoid placing hands or other possible obstructions over
the two filter inlets.
b.2. The "flap" indicator within the airflow device should move into the "green section" which means that there is
®
adequate airflow for PowerCap
to be used.
b.3. In the event of no flow or low flow indicated by a move of the flap into the "red section", first recheck that
battery fitting or charging condition. In the event that there is still no or low airflow, do not use the PowerCap
but contact JSP Ltd for further advice.
Fitting the visor - PowerCap
®
Active™ Lite:
1. Remove the old visor by peeling it away from the Velcro
2. Align the Velcro
®
sections on the visor with the Velcro
that the visor is firm against the underside of the brim.
PowerCap
Active™ Lite
PowerCap
®
3
3
3
3
3
3
3
®
Active™ should be stored in the packaging in which it was supplied. PowerCap
®
will operate at its intended flow rate. The charger
®
meets the TH1P requirements of EN12941 this offers protection against fine non-toxic fibres, fumes and dusts. Operating
®
Active™ has a Minimum Design Flow rate of 140 l/min. To check
®
Active™:-
®
Active™ and fit the Airflow Indicator supplied over the air outlet
®
sections on the inside of the brim.
®
sections on the inside of the brim, ensuring that the visor is central. Press the Velcro
GB
Active IP™
®
3
3
3
3
3
3
3
®
Active™.
Removal
®
Active™ "PowerCable" into
®
,
®
Active™ should be stored
Replacement
®
sections together making certain