6.3 Storage cylinder
Ø 790 mm
995 mm
Illustr. 30 Dimensions of storage cylinder without
insulation
Technical data storage cylinder:
Volume in stand-by motion:
for fresh water station:
Solar heating coil:
Permissible operating pressure: 3 bar
Permissible operating temperature: 95 °C
Geometric design of station nipples: G1 male thread
Geometric design of storage
cylinder nipples:
Weight:
Two integrated loading devices:
1. Return heating circuits
2. Return fresh water station
36
750 mm
type 800 / type 1000
200 l / 250 l
3.1 m² / 3.4 m²
1
G 1
female thread
2
186 kg / 198.5 kg
Separation sheet
Connections heating
circuit groups
Illustr 31 Functional illustrated section
Insulation storage cylinder
Material:
Thickness of material:
Fire protection class:
Thermal conductivity:
Melting point:
– Share of upholstering fibres: about 250 °C
– Share of melting fibres:
– Fusion point:
Insulation jacket
Material:
Thickness of material:
Fire protection class:
Insulation cover
Material:
Fire protection class:
Connection for
Fixing points
electrical
for stations
immersion heater
Connections
solar station
Connections
fresh water
station
Draining facility
Solar
storage cylinder
heating coil
polyester fibres, white
140 mm
DIN 4102 B1
= 0.04 [W/(m*K)]
about 110 °C
when reaching 90 °C
(beginning)
soft foil made of poly-
vinyl chloride
0.4 mm
DIN 4102 B2
polystyrene
DIN 4102 B2