Herunterladen Diese Seite drucken

Weidmuller IE-SW8-M-IP67 Beilage Zum Bedienerhandbuch Seite 19

Ip 67 switch

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4 4 D D e e f f a a u u l l t t s s e e t t t t i i n n g g s s
W W e e b b i i n n t t e e r r f f a a c c e e
Standard IP-Adresse
Username
Password
5 5 T T e e c c h h n n i i c c a a l l d d a a t t a a
E E l l e e k k t t r r i i c c a a l l D D a a t t a a
Power supply
Rated operation voltage
Rated operation capacity
Redundancy
Degree of protection
A A m m b b i i e e n n t t C C o o n n d d i i t t i i o o n n s s
Operation temperature
Operation storage
F F u u n n c c t t i i o o n n a a l l
Compatibility
Data Rate
Signaling
Internal memory
Segmen length (max.)
Supported protocols
192.168.1.110
admin
detmold
The power supply of the IE-SW8-M-IP67 must be
provided exclusively by a power pack which com-
plies with DIN EN 60742 or VDE 0551.
10 ... 36 V DC / 8 ...24 V AC
5 W
redundant power supply, ring structure
IP67
-40°C ... +60°C
-40°C ... +85°C
ANSI/IEEE 802.3
10 und 100 Mbit/s
10 Base-T / 100 Base-TX
256 Kbyte buffer
4 K MAC adresses
100 m (copper)
Profinet RT, Modbus TCP, TCP/IP, EthernetIP