H Y D R O T E C H P E R F O R M A N C E M O N I T O R | A D VA N C E D F I LT R AT I O N S Y S T E M
EN.
01. Priming button
02. Priming chamber
03. Mechanical cartridge
04. Mechanical cartridge cup
05. Chemical cartridge cap
06. Chemical cartridge
07. Chemical cartridge cup
08. AquaStop release lever
09. AquaStop valve lever
10. AquaStop
11. Filter head
16
12. Biological basket cover
13. Biological baskets [G3 x 2/G6 x 3]
14. Filter canister gasket
15. Filter canister
16. Cross rim assembly
17. Rim attachment
18
18. Output nozzle + extension
19. Hosing
20. Spray bar suction cup
21. Spray bars
22. Telescopic intake stem
23. Intake strainer
24. Cartridge lid
25. Impeller assembly
26. Impeller cover + "O" ring
20
01. Ansaugknopf
02. Ansaugkammer
21
03. Mechanischer Filtereinsatz
04. Mechanischer Filterbehälter
05. Chemische Einsatzabdeckung
06. Chemischer Filtereinsatz
07. Chemischer Filterbehälter
08. AquaStop Auslösehebel
09. AquaStop Ventilhebel
22
10. AquaStop
11. Filterkopf
12. Korbabdeckung für biologische Medien
13. Körbe für biologische Medien [G3 x 2/G6 x 3]
14. Filterbehälterdichtung
15. Filterbehälter
23
16. Rahmenbefestigungsteile
17. Rahmenbefestigung
18. Wasseraustrittsstutzen + Verlängerung
19. Schlauch
20. Düsenstrahlrohr-Saughalter
21. Düsenstrahlrohre
22. Teleskop-Ansaugrohr
23. Ansaugkorb
24. Filterdeckel
25. Antriebsmagneteinheit
26. Antriebsmagnetabdeckung + O-Ring
01. Bouton d'amorçage
02. Chambre d'amorçage
03. Cartouche de fi ltration mécanique
04. Boîtier de la cartouche de fi ltration mécanique
05. Couvercle de la cartouche de fi ltration chimique
06. Cartouche de fi ltration chimique
07. Boîtier de la cartouche de fi ltration chimique
08. Manette de dégagement de la soupape AquaStop
09. Manette de la soupape AquaStop
10. AquaStop
11. Tête du fi ltre
12. Couvre-paniers de la masse fi ltrante biologique
13. Paniers de la masse fi ltrante biologique
(G3 x 2/G6 x 3)
14. Joint d'étanchéité du fi ltre
15. Cuve du fi ltre
16. Bloc de raccordement
17. Fixation au cadre
18. Bec de sortie d'eau + rallonge
19. Tuyaux
20. Ventouse du tube diffuseur
21. Tubes diffuseurs
22. Tube d'admission téléscopique
23. Crépine d'admission
24. Couvercle des cartouches du fi ltre
25. Bloc de la couronne
26. Couvercle de la couronne + joint d'étanchéité
IMPORTANT SAFETY INSTRUCTIONS
WARNING - To guard against injury, basic safety precautions should be observed.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
To guard against injury, basic safety precautions should be
observed when handling the Fluval Canister Filter, including
the following:
READ AND FOLLOW ALL
1.
SAFETY INSTRUCTIONS
and all
the important notices on the appliance before using.
Failure to do so may result in damage to the unit.
2. DANGER – To avoid possible electric shock, special
care should be taken since water is employed in the
use of aquarium equipment. For each of the following
situations, do not attempt repairs yourself; return the
appliance to an authorized service facility for service or
discard the appliance.
A. If the appliance falls into the water, DON'T reach for it!
First unplug it and retrieve it. If electrical components
of the appliance get wet, unplug the appliance
immediately.
B. If the appliance shows any sign of abnormal water
leakage or if RCD (or GFCI- Ground Fault Current
Interrupter) switches off disconnect the power supply
cord from mains and remove pump from water.
C. Carefully examine the appliance after installation.
It should not be plugged if there is water on parts not
intended to be wet.
D. Do not operate any appliance if it has a damaged cord
or plug, or if it is malfunctioning or it is dropped or
damaged in any manner. The power cord of this
appliance cannot be replaced; if the cord is damaged,
the appliance should be discarded. Never cut the cord.
The display label of this appliance cannot be replaced; if
the display label is damaged or not fully adherent, the
appliance should be discarded.
E. To avoid the possibility of the appliance plug or
receptacle getting wet, position the appliance to one side
of a wall mounted receptacle to prevent water from
dripping onto the receptacle or plug.
A "drip loop" (see photo) should be arranged by the user
for the cord connecting appliance to a
receptacle. The "drip loop" is that
part of the cord below the level of the
receptacle or the connector if an
extension cord is used, to prevent
water traveling along the cord and
coming in contact with the receptacle.
If the plug or receptacle does get wet, DON'T unplug the
cord. Disconnect the fuse or circuit breaker that supplies
power to the appliance. Then unplug and examine for
presence of water in receptacle.
ENGLISH
3. WARNING - Close supervision is necessary when any
appliance is used by or near children. This appliance
is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use
of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
4. To avoid injury, do not touch moving parts or hot
parts.
5. CAUTION – Always unplug or disconnect all appliances
in the aquarium from electricity supply before
placing hands in water, before putting on or taking off
parts and while the equipment is being installed,
maintained or handled. Never yank cord to pull plug
from outlet. Grasp the plug and pull to disconnect.
Always unplug an appliance from an outlet when not
in use.
6. This is an aquarium fi lter-pump. Do not use this fi lter
pump for other than intended use (i.e.: do not use in
swimming pools, bathrooms, etc.). The use of
attachments not recommended or sold by the appliance
manufacturer may cause an unsafe condition. This
fi lter-pump is not submersible. Never put the fi lter
head in water or under water jets.
• Do not use this fi lter-pump in swimming pools or other
situations where people are immersed.
• This fi lter-pump is suitable for use in water temperatures
up to 35 °C.
• Do not use this fi lter-pump with infl ammable or drinkable
liquids.
7. This fi lter pump is suitable for Indoor Household use only.
Do not install or store the appliance where it will be
exposed to the weather or to temperatures below
freezing.
8. Make sure that the fi lter-pump is securely installed
before operating it. Do not allow pump to run dry.
9. If an extension cord is necessary, a cord with proper
rating should be used. A cord rated for less amperes or
watts than the appliance rating may overheat. Care
should be taken to arrange the cord so that it will not be
tripped over or pulled. The connection should be carried
out by a qualifi ed electrical installer.
SAVE THESE INSTRUCTIONS
10.
For the complete use and understanding of this product
it is recommended that you read this manual thoroughly
and understand all the steps involved. Failure to do so
may result in damage to this product.