The surround consists of the following parts
(Fig. 2):
Part
Description
1
Guide pin Ø6X25
2
Woodscrew Ø6x80 EZ
3
Hex Cap Screw DIN933-M8x16-8.8 Zinc Plated 24 stk
4
Hex Flange Nut M6 DIN6923 8
5
Distance sleeve
6
Brakett front
7
Bracket left side middle uprofile
8
Profile side øvre uprofil
9
Firewall FS 173
10
Bracket for height adjustment
11
Bracket right side middle uprofile
12
screen plate part FS 173
13
Height adjustment screw M8x54
14
Bottom Plate
15
Lower Anchoring Profile
16
Upper Anchoring Profile
17
Upper Binding Profile
18
Top Upper Anchoring Profile
19
Top Front Anchoring Profile
20
Bracket front uprofile
21
Steel plate back low
22
Soapstone side upper R
23
Soapstone front up
24
Soapstone lower front
25
Soapstone side low left
26
Soapstone side lower right
27
Soapstone side middle L/R
28
Soapstone side upper L
29
Sector valve pl compl FS 173
30
Soapstone FS 173
31
Steel support for soapstone
35
Sector valve upper part
36
Sector valve lower part
Optional extras FS 173
34
Floor Plate FS 73 74 NO-SE
33
Floor Plate FS 73 74 DE
32
Floor Plate Glass NO/SE/FI

3.0 Safety

NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are fitted by a qualified installer (see
www.jotul.com for a complete list of dealers).
Any modifications to the product by the distributor, installer
or consumer may result in the product and safety features not
functioning as intended. The same applies to the installation of
accessories or optional extras not supplied by Jøtul. This may
also be the case if parts that are essential to the functioning
and safety of the fireplace have been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.

3.1 Fire Prevention Measures

There is a certain element of danger every time you use
your fireplace. The following instructions must therefore be
Qty
followed:
8 stk
8 stk
• The minimum safety distances when installing and using the
fireplace are given in fig. 1.
4 stk
• Ensure that furniture and other flammable materials are not
4 stk
too close to the fireplace. Flammable materials should not be
1 stk
placed within 1 metre of the fireplace.
1 stk
• Allow the fire to burn out. Never extinguish the flames with
2 stk
water.
2 stk
• The fireplace becomes hot when lit and may cause burns if
2 stk
touched.
1 stk
• Only remove ash when the fireplace is cold. Ash can contain
1 stk
hot embers and should therefore be placed in a non-
1 stk
flammable container.
1 stk
• Ash should be placed outdoors or be emptied in a place where
1 stk
it will not present a potential fire hazard
1 stk
1 stk
3.2 Floor
1 stk
1 stk
2 stk
Foundation
2 stk
1 stk
Make sure that the foundation is strong enough to bear the
2 stk
weight of the fireplace (110 kg + 274 kg).
2 stk
We recommend the removal of any flooring that is not attached
1 stk
to the foundation ("floating floors") beneath the installation.
1 stk
2 stk
Requirements for protection of wooden flooring
1 stk
beneath the fireplace
1 stk
1 stk
The product has integrated floor protection and may therefore
1 stk
be placed directly on a wooden floor.
1 stk
1 stk
Requirements for protection of combustible
floors in front of the fireplace
1 stk
The front plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions and
1 stk
installation requirements.
1 stk
For Norway: Minimum 300 mm in front of the door and width
at least the same as the door.
3.3 Walls
Distance to walls made of combustible materials - see Fig. 1 (Jøtul
FS 173).
The fireplace may be used with a semi-insulated flue pipe provided
the distances between the fireplace and walls made of combustible
materials are as shown in Fig. 1 (Jøtul FS 173).
NB: Ensure that furniture and other combustible materials are
not too close to the fireplace. Combustible materials must not
be placed within 1000 mm of the fireplace opening.
3.4 Ceiling
If the ceiling above the fireplace is made of a combustible
material, the minimum distance between the fireplace and
ceiling must be 650 mm. i.e. a minimum ceiling height of 2350
mm.