Herunterladen Inhalt Inhalt Diese Seite drucken

VEGA VEGAPULS 65 Betriebsanleitung Seite 56

Vorschau ausblenden Andere Handbücher für VEGAPULS 65:
Inhaltsverzeichnis

Werbung

10 Anhang
Min./max.-adjustment: Level at 'Cal_point_lo'. When writing 'Cal_level_lo' and 'Cal_type' = 1
-
(Online), the 'Cal_point_lo' is automatically set to the current sensor value. The unit is defined in
'Level_unit'
cal_type
l
Min./max.-adjustment: Defines type of calibration: Dry: no influence of sensor value. Online:
-
current sensor value determines 'Cal_point_hi/lo'
level
l
Value after min./max.-adjustment
-
level_unit
l
Unit code of 'Level', 'Level_offset', 'Cal_level_hi', 'Cal_level_lo'
-
level_offset
l
Offset that is added to the 'Level' value. Unit derives from 'Level_unit'
-
SENSOR_OFFSET
l
Offset that is added to the 'Sensor_value'. Unit derives from 'Sensor_range.unit'
-
end_of_operation_range
l
Set up to suit the process conditions
-
begin_of_operation_range
l
Set up to suit the process conditions
-
product_type
l
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized this
-
parameter cannot be written
liquids_medium_type
l
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized this
-
parameter cannot be written
solids_medium_type
l
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized this
-
parameter cannot be written
liquids_vessel_type
l
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized this
-
parameter cannot be written
solids_vessel_type
l
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized this
-
parameter cannot be written
fast_level_change
l
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized this
-
parameter cannot be written
first_echo_factor
l
Set up to suit the process conditions.
-
pulse_velocity_correction
l
Set up to suit the process conditions.
-
echo_quality
l
Signal/Noise ratio
-
empty_vessel_curve_corr_dist
l
56
VEGAPULS 65 • Foundation Fieldbus

Werbung

Inhaltsverzeichnis
loading