1� About this document
Please read carefully and keep in a safe place�
– Under copyright. Reproduction either in whole or
in part only with our consent.
– Subject to change in the interest of technical
progress.
Symbols
!
Hazard warning!
Reference to other information in
...
the document�
2� General safety precautions
Disconnect the power supply before
!
attempting any work on the unit�
• Installing these lights involves work on the mains
voltage supply; installation must therefore be
carried out professionally in accordance with the
applicable national wiring regulations and electri-
cal operating conditions (
-VDE 0100,
D
a
-ÖVE/ÖNORM E 8001-1,
-SEV 1000)
h
• The floodlight enclosure heats up when the light
is on. Only adjust the angle of the LED head
once it has cooled down.
• The light must be positioned so that it is not
expected that anybody can stare into the light
for any prolonged period from a distance of less
than 0.3 m.
3� XLED PRO Square / Wide
Proper use
– Sensor-switched floodlight with LEDs as light
source.
– Suitable for wall mounting outdoors.
– Data line (D-line, optional) for synchronous
switching.
The XLED PRO Square and XLED PRO Wide
sensor-switched LED floodlights are fitted with
infrared sensors. These floodlights provide a basic
brightness function by means of additional light
lines. In stand-alone mode, the slave version of this
LED floodlight must be switched ON and OFF via a
switch/button to be provided on site. As an option,
main and basic light can be switched ON and OFF
in synchrony via an additional data line (D-line)
between sensor-switched LED floodlights (master-
master) and slave LED floodlight (master-slave).
Models
– XLED PRO Square XL
– XLED PRO Square
– XLED PRO Wide XL
– XLED PRO Wide
Package contents
XLED PRO Square (Fig� 3�1)
XLED PRO Wide (Fig� 3�3)
Product dimensions
XLED PRO Square (Fig� 3�2)
XLED PRO Wide (Fig� 3�4)
Floodlight components (Fig� 3�5)
A
Floodlight head
B
Basic light level LED
C
Enclosure
D
Function setting
- Basic light level
- Time setting
- Twilight setting
E
Status LED
F
IR sensor
G
Cover on controls
H
Wall mount
I
Plug connection
4� Installation
Connecting the mains power supply lead
(Fig� 5�8)
The mains power supply lead is a 3-core cable:
L
= phase conductor
(usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
D = D-line (data line) optional
If you are in any doubt, identify the conductors
using a voltage tester; then disconnect from the
power supply again. Connect phase (L) and neutral
conductor (N) to the terminal block.
– 12 –
Wiring diagram (Fig� 4�1 / 4�2)
Reach diagram (Fig� 4�3)
Note:
A mains switch for switching the light ON and
OFF can be installed in the mains supply lead.
This is required for the manual override function
➜ "6� Functions"
Important:
Mixing up the connections will produce a short
circuit later on in the floodlight or your fuse box. In
this case, you must identify the individual conduc-
tors once again and re-connect them.
The light source of this luminaire cannot be
replaced. If the light source needs to be replaced
(e.g. at the end of its service life), the complete
luminaire must be replaced.
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Aiming the sensors (Fig� 5�1)
The most reliable way to detect movement is given
by mounting the light to point across the direction
in which people walk and by making sure no
obstacles (e.g. trees, walls etc.) interrupt the line
of sensor vision.
Mounting procedure
• Select appropriate site of installation, giving
consideration to reach and detection of move-
ments (Fig� 5�2)
• Switch OFF power supply (Fig� 5�3)
• Undo retaining screws (Fig� 5�4)
• Detach enclosure from wall mount (Fig� 5�4)
• Mark drill holes (Fig� 5�5)
• Drill holes and insert wall plugs (Fig� 5�6)
– Concealed installation (Fig� 5�6)
– Surface-mounted installation (Fig� 5�7)
• Connect conductors (Fig� 5�8)
• Fit enclosure (C) onto wall mount (G).
Pay attention to plug connection (H) (Fig� 5�9).
• Screw in retaining screws (Fig� 5�9)
• Switch ON power supply (Fig� 5�10)
• Open cover over controls (Fig� 5�11)
• Make settings ➜ "6� Function"
6� Function
Once you have installed the wall mount and con-
nected the floodlight to the power supply, it can
be put into operation. If the floodlight is put into
operation manually at the light switch, it will switch
OFF after 40 s for the calibration phase and is then
activated for sensor mode. It is not necessary to
operate the light switch a second time.
Factory settings
Basic brightness: OFF
Time setting: 5 seconds
Twilight setting: daylight mode
Function (Fig� 6�1)
Basic brightness (Fig� 6�1 / J)
Basic brightness by means of basic light LEDs
provides a low level of illumination. The main light
is only switched on for the time selected when
movement occurs in the detection zone. The light
then switches to the selected level of basic
brightness
– OFF
= no basic light
– 10 min = basic light for 10 min upon expiry of
the time selected
– " "
= basic light all night
Time setting / stay-ON time (Fig� 6�1 / K)
The time you want the floodlight to stay on for
(main light) is infinitely adjustable from approx. 5 s
to a maximum of 15 min. Any movement detected
before this time elapses will restart the timer.
Note: whenever the light switches OFF, motion
detection is interrupted for approx. 2 s. The light will
only switch ON in response to movement once this
period has elapsed.
Twilight setting / response threshold (Fig� 6�1 / L)
The floodlight's chosen response threshold can be
infinitely varied from approx. 2-1000 lux.
– Control dial set to
= daylight mode (depending
on ambient brightness)
– Control dial set to
= twilight mode (approx. 2 lux)
Manual override function (Fig� 6�2)
If a mains switch is installed in the mains supply
lead, the following functions are provided in
addition to simply switching light ON and OFF:
– 13 –