Please filter salt water before filling it into the unit. Otherwise, it may damage the titanium pipe
of the evaporator.
6.
If the machine won't be used for a longer period, please cut off power supply of the unit.
7.
Periodically, check and clean the condenser for assuring the performance of the unit according
to the working environment conditions.
8.
Please use soft pipe to install the inlet and outlet water pipe with reasonable fixing, thus to avoid
a damage of the water inlet and outlet due to vibration of the product. Please make sure that
the tubes are heat-resistant.
9.
If it is installed indoors, please make sure that the exhaust air is directed outdoors.
6.
Safety Precautions
1.
Please ask a professional technician to install the unit to avoid any problems with fire, electronic
shock, physical injury, leakage or damage of the product as a result of mistakes.
2.
Use power supply correctly, please connect the ground wire.
3.
If there's a fault, stop the unit immediately and cut off power supply. Then consult the
distributor.
4.
Please don't press the power switch with wet hand to avoid an electric shock.
5.
Maintenance and/or repairs should be done exclusively either by a service engineer or by the
manufacturer.
6.
Please don't insert hard objects into the unit. This may damage the heat exchanger.
7.
Assure that the water pump and pipes are installed correctly. Otherwise, the power of the
product may decrease.
8.
Place the unit on an even and solid surface, protecting it from falling down.
9.
Avoid installing the product in a public space. If it is required to install it in a public place, assure
to keep it far away from children. It is not allowed to install it in flammable and explosive space.
7.
Troubleshooting
Fault and Reasons
Compressor doesn't start or stops shortly after
starting:
1. Power failure or voltage exceeds ±10% rated voltage. Supply power, check voltage.
2. Thermostat fault.
3. Fuse is damaged.
4. Fan doesn't work or water pump can't start.
Compressor stops when working:
1. Compressor temperature is too high.
2. Compressor is overloaded, overload protection is
activated.
Cooling (heating) performance drops or the system
can't cool or heat at all:
1. Inlet air temperature of condenser is too high.
2. Fish tank has poor heat preserving performance.
3. Cooling liquid is missing or compressor damaged.
Solutions
Repair or replace.
Replace.
Check the fan and water pump.
Check the dust on the heat radiator in
the back.
Improve the ventilation in the room.
Make sure there is adequate ventilation.
Improve the environment of fish tank.
Maintenance by a specialist.