Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting Additional Electrical Equipment - Superrollo SR40070 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

i

Connecting additional electrical equipment

When working on electrical systems there is
a risk of danger to life due to electrocution.
◆ The connection of additional electrical equipment
must only be carried out by a qualified electrician.
◆ Before opening the protective cover always dis-
connect the equipment from the mains power supply
and check that the system is free of voltage.
Accessories from other manufacturers may
result in malfunctions or damage to property.
◆ Use only original accessories. A separate source
voltage at the screwtype terminal for the external
switch will result in a short circuit and will destroy
the door operator's electronics.
◆ Do not connect any separate source voltages to the
terminal for the external switch. The terminals are
potential-free contacts.
TA70
( 1 )
Key
(1) =
main board
(2) =
infrared light barrier (optional)
(3) =
external switch (optional)
(4) =
pass door contact
58
If the external buttons are not connected
properly, the operational safety of the
equipment is at risk.
Always mount the internal button, programming
button, etc.:
◆ outside the reach of movable parts
◆ within visibility of the door
◆ at a height of at least 1.5 metres
( 4 )
( 3 )
NOTE!
Remove the respective factory installed bridge before
connecting a light barrier or a pass door contact.