Werbung

• RESET - channel: 16
• LAMP CONTROL (only with option LDmx On) - channel: 17
IMPORTANT: Alpha Spot 300 is not provided with hot restrike igniter
ON
ON
OFF
OFF
BIT
%
EFFECT
255
100
COMPLETE RESET
Complete reset is activated passing
throug the unused range and staying
5 seconds in complete reset levels.
128
50.0
COMPLETE RESET
127
49.7
PAN / TILT RESET
Pan / Tilt reset is activated passing
throug the unused range and staying
5 seconds in Pan / Tilt reset levels.
77
30.0
PAN / TILT RESET
76
29.7
EFFECTS RESET
Effects reset is activated passing
throug the unused range and staying
5 seconds in Effects reset levels.
26
10.0
EFFECTS RESET
25
9.7
UNUSED RANGE
0
0.0
BIT
%
EFFECT
255
100
LAMP ON
The function is activated
staying 5 s in Lamp ON levels.
180
70.5
LAMP ON
179
70.0
UNUSED RANGE 2
101
39.5
100
39.0
LAMP OFF
The function is activated
passing throug the unused
range 1 and staying 5s in
Lamp OFF levels.
26
10.0
LAMP OFF
25
9.7
UNUSED RANGE 1
0
0.0