INSTALLATION

Attachment

Before attaching the device, make sure that the installation area can hold a minimum point load of 10 times
the device's weight.
The device must only be installed absolutely planar at a vibration-free, oscillation-free and fire-resistant
location. Make sure that the device is installed absolutely planar by using a water-level.
The device must be installed out of the reach of people.
The device must always be installed via all fixation holes. Do only use appropriate screws and make sure
that the screws are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
Procedure:
Step 1: The holes for the installation are on the mounting bracket.
Step 2: Pay attention to the correct mounting position for the floodlight. Only mount it with the motion
detector pointing downwards.
Step 3: The ideal installation height is between 2 and 4 meters depending where it is installed and the
ambient conditions (layout of access routes to be monitored, etc.)
Step 4: Hold the mounting bracket onto the location where the device is to be installed.
Step 5: Mark the boreholes with a pen or a suitable tool.
Step 6: Drill the holes.
Step 7: Hold the mounting bracket in the desired position and fix it.
Step 8: Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
Before taking into operation for the first time, the installation has to be approved by an expert!

Connection with the mains

Connect the device to the mains with the power plug. The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
Attention! The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Permanent installation is recommended!
DANGER TO LIFE!
International
L
N
12/14
00071238.DOC, Version 1.1