11.8 The inlet hose filters and
the valve filters
It could be necessary to clean the filters
when:
• The appliance does not fill with water.
• The appliance fills with the water for a
long time.
To clean the cold water inlet filters:
2
1
8.
Make sure that the impeller of the
pump can turn. If this does not oc-
cur, contact the service centre.
9.
Clean the filter under the water tap
and put it back in the pump into the
special guides.
10.
Make sure that you tighten correctly
the filter to prevent leakages.
11.
Put the flap back and close the drain
pump door.
• The indicator of button
the display shows the related alarm.
Refer to 'Troubleshooting'.
WARNING!
Disconnect the mains plug from
the mains socket.
1.
Close the cold water tap.
2.
Remove the cold water inlet hose
from the cold water tap.
3.
Clean the filter in the cold inlet hose
with a stiff brush.
4.
Remove the cold inlet hose behind
the appliance.
5.
Clean the filter in the cold valve with
a stiff brush or a towel.
4