Herunterladen Inhalt Inhalt Diese Seite drucken

Sterling Power Products AB12160 Einbauanleitung Und Bedienungsanleitung Seite 8

Vorschau ausblenden Andere Handbücher für AB12160:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6
OPEN
LEAD ACID
GEL-
BATTERIES
(EXIDE SPECIFICATION)
SEALED LEAD
ACID & AGM
GREEN FLASHING
GEL & AGM
(US SPECIFICATION)
ENGINE STARTER
BATTERY
8
B
ASIC
engine
alternator
7
fuse
ON
LED
MAX. CHARGING
ABSORBTION
COLOUR
VOLTAGE
14.8V / 20°C
1 - 10 HRS.
YELLOW
14.4V / 20°C
12 - 24 HRS.
GREEN
14.4V / 20°C
RED
14.2V / 20°C
4 - 10 HRS.
FOR 5 SEC.
ENSURE ALL NEGS ARE COMMON
S
W
YSTEM
IRING
+
WHAT CABLE TO USE IN sq mm
A charger or inverter up to
0-25 amps
25-45 amps
45-85 amps
85-125 amps
125- 180 amps
180-330 amps
Please note that if there is a problem obtaining for example 90 sq mm cable,
simply use 2 x 50 sq mm or 3 x 35 sq mm. The cable is simply copper, and
all you require is the copper. It does not matter if it is one cable or 10 cables
as long as the cross-section adds up. Performance of any product can be
improved by thicker cable, so if in doubt round up.
FLOATING
TIME
VOLTAGE
13.65V / 20°C
13.8V / 20°C
4 - 8 HRS.
13.65V / 20°C
13.5V / 20°C
+
cable run distance 0-1.5 mtr
6 mm sq
16 mm sq
25 mm sq
35 mm sq
50 mm sq
70 mm sq
DOMESTIC BATTERY SYSTEM
1.5 - 4 mtr
10 mm sq
25 mm sq
35 mm sq
50 mm sq
70 mm sq
90 mm sq