1) Key "volts"
This key will call the above mentioned standard screen. When the
standard screen is displayed and this key is pressed again, the
display shows the time since the unit has been switched on (ON)
as well as the cumulative boost time (BOOST).
2) Key " "
The display will show the voltage and the charging current of the
starter battery and the calculated rest time of the absorption
charge.
3) Key "setup"
Pressing this key once will display selected battery type and the
charging stage currently being active. When this key is pressed
again, the boost will be displayed in per cent. Pressing this key a
third time will show the software release of the remote control (R)
and the charger (C) as well as the system voltage.
4) Key"temp"
Pressing this key once will display the temperature of the
alternator (ALT) and the temperature of the battery (BAT). (In
case of the temperature sensors not being used, the display will
show 20 deg C.) If this key is pressed again, the left hand (LHS)
and right hand (RHS) interior case temperatures will be
displayed.
LED Display on Remote Control
1) System Trip (red)
The charger has tripped and switched off because of a non-
recoverable fault. The system has to be restarted manually.
B
A
BOX INSTALLATION INSTRUCTIONS
SLIDE PARTS A TO EXPOSE SCREW HOLES
FOR FLUSH MOUNT, REMOVE PART B
FOR SURFACE MOUNT KEEP PART B
AFTER INSTALLATION REPLACE PARTS A
2) System Disengaged (yellow)
The alternator or the charger itself is overheated and the unit has
been deactivated temporarily. The charging process will
automatically be continued when the temperature has come
down. It is not necessary to restart the system manually. If this
problem occurs frequently, improve the ventilation of the unit or
the alternator respectively.
3) Low Voltage Warning (yellow)
The input voltage of the charger is too low and insufficient for its
proper functioning. Please check your connections and the output
voltage of your alternator.
4) System within Limits (green)
All system parameters and functions are normal. The charger is
working correctly.
Special Functions
Auto-Pause Function
The alternator-to-battery charger is programmed in such a way
that the boost function is suspended for the first five minutes after
switching on and every 20 minutes for a period of three minutes
thereafter. This is called the auto-pause function which gives the
starter battery an extra charge. It can be manually deactivated by
pressing the "volts" and the " " keys at the same time. To
confirm you will hear a beep and see a text message on the
screen.
Every time the unit is switched off and back on again, the auto-
pause function will be reactivated automatically.
7