General
UKV 500 has several different areas of use.
UKV 500 can be used with external control of the heating
system.
The heat pump then charges UKV with floating or fixed
condensing. The external control function controls the
heat distribution from UKV 500 to the consumer. If the
flow to the heating system can be restricted using radiator
thermostats for example, install a UKV 500 as an interme-
diate tank. This ensures a secure flow for the heat pump.
UKV 500 also allows a greater flow to the heating system
than across the heat pump. In some installations, so-called
heat spikes occur as a result of movements during temper-
ature changes. To eliminate temporary temperature
changes, and thereby prevent heat spikes, install a UKV
500 after the heating installation. UKV 500 can also be
used to increase the system volume and prevent malfunc-
tions.
INSTALLATION INSTRUCTIONS
UKV 500
Removing the insulation
The insulation on UKV 500 can be removed to facilitate
work in confined spaces
1. Remove all screws along the joining plate.
2. Lift off the top cover.
3. Remove the insulated jacket.
4. Pull the insulated parts straight out.
Carry out assembly in reverse order.
UKV 500
GB
9