Inhaltsverzeichnis / Index Sicherheitshinweise Safety and installation notes! Beschreibung der Anschlüsse Description of cable connections - Kabelanschlüsse - Cable connections - Voreinstellung IP-Adresse, Sprache - Pre settings IP address, Language 32-33 - Freischalten der IPTV Option - IP TV activation code - Betriebssoftware laden - Loading system software - Graphische Oberfläche...
Sicherheitshinweise - bitte beachten! Safety and installation notes – please observe! Achtung Caution Die angegebene Betriebsspannung 180-265 VAC; The mains voltage must match the rated input voltage 50/60 Hz muß mit der Netzspannung übereinstimmen. of the unit (180-265 VAC; 50/60 Hz). Anschlußkabel —...
Anschlüsse / Connectors WISI STREAMLINE Multiplexer POWER INPUT TEST FUSE T2A/250 VAC RF out Ethernet Option: Eingangsmodule Input modules 230 VAC Kundenspezifisch Customer device DVB S / S2 / T / C IP Modul Modul Ethernet SDI MPEG2/ DVB-Dual S, AV MPEG 2 HW 2.0000...
Kabelanschlüsse - Betriebssoftware Kabelanschlüsse - HF-oder AV-Signal an das entsprechende Eingangsmodul anschließen (Frontend). - Ethernet-Anschluß OTxx mit Ethernet am PC verbinden. - Betriebssoftware (CD-Rom) auf PC aufspielen. Freier Speicherplatz ca. 1 Gb Fig. 1 Fig. 2 Graphische Oberfläche - OT Konfiguration Fig.
Seite 6
IP Adresse bekannt - Fig.1; Schaltfläche 1 „Programm Einstellungen“ und“ Kommunikation“ klicken. - Fig. 2; IP eingeben und Haken bei „Automatisch mit OT verbinden“ setzen. - Übernehmen und mit OK speichern. Broadcast Broadcast sucht alle OT‘s und listet sie in der Tabelle nach IP- und MAC-Adresse auf. - Fig.4;...
Freischaltcode für IP-TV Modul Fig. 7 Freischalten der IP-TV-Funktionen Schaltfläche 7. Den Freischaltcode für dieses Feature bekommen Sie manfred.kling@wisi.de unter der e-mail Adresse: Halten Sie hierzu bitte Ihre Mac-Addresse bereit. Eingangsmodule DVB-IP Modul Fig. 2 - MAC-Adresse: Anzeige der DVB-IP Modul MAC-Adresse - Multicast £...
Transportstromanalyse Fig. 3 TSAnalyse - Fig. 3 - Aktuellen TS aus dem Gerät laden. - oder TS aus Datei laden. Hierzu: Haken im Feld „Aus Debug-Datei“ setzen. In der „PSI/SI-Table Status“ -Anzeige wird der korrekte Status mittels grüner LED angezeigt. Rot deutet auf einen Fehler hin.
Services - Information Fig. 4 Im Service-Feld werden die im Transport-Strom enthaltenen Programme mit Video und Audio-Stream ange- zeigt. Das Übernehmen der Programme mit den entsprechenden Video- Audioströmen in den Multiplexer erfolgt durch Anklicken des Kästchens. Im OT-Modul unter PID Remapping werden diese Programme gelistet.. Am unteren Bildrand wird die Gesamtdatenrate aller Services angezeigt.
NIT - Information Fig. 5 Die NIT - Network Information Table enthält die Spezifikationen der Transponder und der Programme, die in einem Datenstrom übertragen werden, wie z. Bsp - Sendefrequenz siehe Fig. 5 - Symbolrate - Informationen für Receiver und Settop-Boxen - 12 -...
SDT - Information Fig. 6 Ähnlich wie die NIT enthält die Service Description Table die Diensteparameter, die für jeden Dienst im MPEG- Strom übertragen werden z. Bsp. Programmname, Providername PAT - Information Fig. 7 In der PAT - Program Association Table werden alle PMT-PID gelistet. - 13 -...
PMT - Information Fig. 8 PMT - Program Map Table enthält Informationen über die Programme, wie Verweise auf die zu einem Pro- gramm gehörenden Video-, Audio- und Datenstreams. CAT - Information Fig. 9 CAT - Conditional Access Table - CAT (Conditional Access Table); enthält Informationen über zugriffsberechtigte Fernsehprogramme.
Live! - Information Fig. 10 Live! bietet die Beurteilung des TS über einen Zeitintervall an. Hierzu TS laden. - Alle PIDs wählen: Mit rechter Maustaste ins farbige Feld klicken und - Alle PIDs wählen - anklicken. - Keine PIDs wählen: Mit rechter Maustaste ins farbige Feld klicken und - Keine PIDs wählen - anklicken.
Hinweis: Bei HW-Version 1.000: CBR-Einstellung 6 Mbit/s - GOP Struktur: IIIIIIIIIII, IPPPPPPPPPP, IPIPBPBPP, BIPBPBPB (Group of picture) - Eingangstransportstrom: o.k. - Service Provider Name: persönlicher Name eintragen: WISI Streamline - Service Name: persönlicher Service Name eintragen:„TV Wellness“ - Audio Signal: Aus / Ein - Testbild:...
1.504, 3.008, 4.512, 6.000, 9.000 (Constant Bitrate) - VBR Bitrate:: 1.504-3.008 MBit/s, 3.008-4.512 MBit/s, (Variable Bitrate) 4.512-6.000 MBit/s, 6.000-9.000 MBit/s, - Service Provider Name: persönlicher Name eintragen: WISI Streamline - Service Name: persönlicher Service (Programm) Name eintragen: z.B. „TV Wellness“ - Audio Signal: Aus / Ein...
Seite 21
Fig. 2 - TS Clock Teiler: Teiler: 1-13.5 MBit/s (nur Anzeige) - Eingangs Status: Rot: kein Audio und/oder Video-Eingangssignal vorhanden Grün. Eingangssignal o.k. - Clock Status: Beide auf grün: Board o.k. Einer oder beide auf rot: Board failure - Audio Kanal Links/Rechts Auswahl der Quell Digital Gruppe 0..9, A, B Analog und 1 kHz Test-Signal - Verstärkung:...
CI Modul Fig. 1 Darstellung der im Transportstrom enthaltenen verschlüsselten Sender. Drücken der Taste „Auslesen“ stellt die Senderliste neu dar. Auswahl der Programme, die entschlüsselt werden sollen. Häkchen setzen. Sie werden in Tabellenform im Fen- ster „watching events“ dargestellt. Fig. 2 Entschlüsseln der PIDs.
Autom. PID Remapping Fig. 3 Folgende Einstellung Fig. 3 sind möglich Automatisch = manuell. Alle Fehler (doppelte PIDs) werden vom Benutzer korrigiert. 1388; Automatisch; Start PID Alle remappen: Alle doppelten PIDs und SIDs werden automatisch remapped. Dazu wird die Start PID hochgezählt. ...
PID Remapping Fig. 4 Fig. 5 Programme übernehmen - Programm -und Providername ändern Programme bzw. Audio- Videoströme, die umgesetzt werden , wählt man durch Setzen eines Hakens im Ein- gangsmodul (hier DVB-S, Fig. 4) aus. Sie werden in die PID Remappingtabelle übernommen (Fig. 5). Name ändern.
NIT-Editor Fig. 7 Die Parameter der NIT stehen in der „Cable Delivery Description“ Tabelle. Über Import können aus anderen OTxx-Geräten NITs hinzugeladen werden. Ein Export-Button ermöglicht das Exportieren des Kabel-Transportstromes. + - Hinzufügen oder Löschen von Transportströmen, die auch importiert wurden Klicken Sie in der Tabelle unterhalb „TS ID“...
Programmierung Fig. 8 Überprüfen Sie nochmals alle Einstellungen bevor die Programmierung eingeleitet wird. In der „Event Information Table“ das Modul auswählen aus dem der Transportstrom übernommen wurde. Folgende Einstellungen vornehmen: EIT übernehmen aus Transportstrom von TDT/TOT übernehmen aus Transportstrom von PSI/SI Tabellen - Filter Optionen ...
IP-TV Fig. 1 Freischaltcode siehe Seite 8! IP TV - erlaubt Ihnen das Senden von Datenströmen auf a) eine „Eigene Adresse“ (steuernder PC) Port angeben. b) definierte „IP-Adresse“, die als Ziel Parameter angegeben wird. Dabei wird auch die zugehörige MAC-Adres- se eingeblendet.
IP address known - Fig. 1; click on Button 1 “Program Settings” and “Communications”. - Fig. 2; Enter IP and check “Connect with OT automatically”. - Accept and save with OK. Broadcast - Fig. 4; Button 4 “Search network for OT Remux”. - Click on Broadcast and confirm with “Search”.
Fig. 5 Change IP address Assign IP address IP Adresse unknown - Assign a temporär IP-address to MAC address (refer to type lable). - Fig 4; Buttom 5. Select menue „Assign IP Address“. - Insert MAC-address 12digit (without hyphen) and IP-address. (Fig. 5) - Change IP-address.
IP-TV Module with Activation Code Fig. 7 Activation code for IP-TV Option Button 7. E-mail address for your Activation code to: manfred.kling@wisi.de Please hold the MAC address ready. Input modules (Front end) DVB-IP Module Fig. 2 - MAC Address: Shows the DVB-IP module MAC address - Multicast £...
DVB-S / S2 Module Front end Fig. 1 Fig. 2 - Input frequency (MHz): 12460 (Adjustment unnecessary with customer-specific configuration) - Symbol rate (kS/s): 27500 (Adjustment unnecessary with customer-specific configuration) - LNB LO Frequency (MHz): 10600 LO frequency – select 9750 or 10600 MHz. - DVB system, modulation and code rate: Set modulation type (DVB-S2 module only)
TSAnalysis Fig. 3 TS Analysis - Fig. 3 - Load the current TS from the device - or load the current TS from file. To load from file: Tick the box next to “From debug file”. In the “PSI/ISI Table Status”...
Service - information Fig. 4 The Service field displays the programs contained in the transport stream, with their video and audio streams Confirm the selected programs and the corresponding video and audio streams by clicking the relevant selection boxes. The overall data rate for all services is displayed at the bottom edge of the screen. This data rate should not exceed 90% of the data rate shown in the multiplexer.
NIT - information Fig. 5 The NIT – Network Information Table – contains the specifications of the transponders and the programs transmitted in a data stream, e.g. - Transmission frequency, see Fig. 5 - Symbol rate - Information for receivers and set-top boxes - 38 -...
SDT - information Fig. 6 Like the NIT, the Service Description Table (SDT) contains service parameters that are transmitted for each service in the MPEG stream, e.g. program name, provider name etc. PAT - information Fig. 7 The PAT – Program Association Table – lists all the PMT-PIDs. - 39 -...
PMT - information Fig. 8 The PMT – Program Map Table – contains information on the programs, such as cross-references to the video, audio and data streams belonging to the relevant program. CAT - information Fig. 9 CAT – Conditional Access Table – contains information on TV programs with limited access rights (i.e.
Live! - Information Fig. 10 Live! offers assessment of the TS over a time interval. For this, load TS. - Select all PIDs: Right click the mouse on the colored field and click on – Select all PIDs. - Do not select any PIDs: Right click the mouse on the colored field and click on –...
- GOP Structure: IIIIIIIIIII, IPPPPPPPPPP, IPIPBPBPP, BIPBPBPB (Group of picture) - Transport stream: o.k. - Service Provider Name: List your personal provider name: WISI Streamline - Service Name: List your personal name: „TV Wellness“ - Audio Signal: On / Off...
1.504, 3.008, 4.512, 6.000, 9.000 (Constant Bitrate) - VBR Bitrate:: 1.504-3.008 MBit/s, 3.008-4.512 MBit/s, (Variable Bitrate) 4.512-6.000 MBit/s, 6.000-9.000 MBit/s, - Service Provider name: List your personal provider name: WISI Streamline - Service Name: List your personal name:: „TV Wellness“ - Audio Signal: On / Off...
Seite 46
Fig. 2 - TS Clock factor: Factor: 1-13.5 MBit/s (only display) - Input State: Red: no audio and/or video-input signal Green. Input signal o.k. - Clock State: Both set to green: Board o.k. One or both set to red: Board failure - Audio channel Left/Right Selection of the Source Digital Group 0..9, A, B Analogue and 1 kHz test signal...
CI Module Fig. 1 Depiction of the encoded transmitters in the transport stream. Pressing the “Readout” button causes the transmitter list to be displayed anew. Select of the programs that are to be decoded. Make a checkmark. They are depicted in tabular form in the “Watching Events”...
Modulator Modules QAM Module Fig. 1 - Output frequency (MHz): 474.0 (setting not required for customer-specific configuration) - Symbol rate (kS/s): 6900 - Output attenuation (dB): 0-10 - Netto data rate (kBit/s): 381531(calculated from symbol rate and Modulation). Refered to 188 Bytes/MPEG paket - RF signal: On, Off - QAM spectrum:...
OT configuration Module General Fig. 1 Output data format: 188, 204 Bytes/packet. Default setting 188 Data rate (bits/s): Output data rate multiplexer; reference to setting output data format Net data rate (bits/s): Net output data rate – multiplexer; reference to 188 Bytes Transport stream overflow: Green: correct;...
Autom. PID Remapping Fig. 3 Following settings Fig. 3 are possible Automatic = manual. All errors (double PIDs) are corrected by user. 1388; Automatic; Start PID Remap all: All double PIDs and SIDs are remapped automatically. To do this, the start PID is incremented. ...
PID Remapping Fig. 4 Fig. 5 Take over programs - Change program -and provider name Programmes etc. audio- video streams to be converted, select with a hook at the input module (refer DVB-S, Fig. 4) They are taken over to the PID Remapping table (Fig. 5). Change name.
NIT editor Fig. 7 Discribes the content of the NIT in the “Cable Delivery Description” Table. Via import, it is possible to load NITs or OTxx devices in addition. An export button permits exporting of the cable transport stream. + - Addition or deletion of transport streams. Click in the table underneath “TS ID”, in the example, on 0x0000.
Programming Fig. 8 Check all settings once again before starting programming. In the “Event Information Table”, select the module from which the transport stream was taken over. Make the following adjustments: Take over EIT from transport stream from Take over TDT/TOT from transport stream from PSI/SI Table –...
IP-TV Fig. 1 IP TV (please refer to page 34 „IP TV activation code) - to transmit data streams to: a) PC or OT b) defined „IP address“, inserted as prompt address. MAC address is displayed. MAC address shows 00-00-00-00-00-0 — no external PC or OT found. SET different IP address again! Set „Port“...
Spezifikationen / Specifications ASI in/out, ASI dual in ASI - Receiver Eingang / ASI - receiver input Datenformat / Data format DVB A010 ASI-C, EN50083-9 Bitrate 270 Mb/s ASI-Betriebsart / ASI mode Burst or continuous Packet / Packet framing 188 / 204 byte per packet Empfindlichkeit / Sensitivity 200mV (p-p) Max.
Seite 58
Audio-Eingang / input Eingangsformat / Input format Analog (left, right) 83-9 Eingangspegel / Input level 500 mVeff / 600 Ohm Abtastfrequenz / Sampling frequency 32 / 44,1 / 48 kHz Emphase / Emphasis 50 / 75µs / CCITT J.17 Encoding standard MPEG 1 L1/2 ISO/IEC 13818-3 Bitrate / Bit rate up to 448 kbit/s...
Seite 59
Innerer Fehlerschutz / FEC inner code Conv.,K=7,R=1/2,2/3,3/4,4/5,6/7,7/8,8/9 Äusserer Fehlerschutz / FEC outer code RS (204,188,8) Spektrale Inversion / Spectral inversion C-/KU-band Interleaving Conv.,I=12 Lock-Anzeige / Lock indicator Frontplatte / front panel LED DVB-T 75 Ω Eingangsimpedanz / Input impedance Eingangsfrequenzbereich / Input frequency range 146 –...
Seite 60
SDI-MPEG Encoder Video - Eingang / input Eingangsformat / Input format SDI SMPTE 259M-C 270 Mbit/s 625Z with embedded audio SMPTE 272 M-A Eingangspegel / Input level 200 mVpp without equalizer 75 Ω Eingangsimpedanz / Input impedance Encoder Encoder Standard / Encoding standard MPEG 2 ISO/IEC 13818-2 MP@ML (4:2:0) Bitrate / Bit rate...
Seite 61
QAM Modulator 75 Ω Ausgangsimpedanz / Output impedance Ausgangsfrequenzbereich / Output frequency range 45 - 862 MHz Ausgangsfrequenzschritte / Output frequency steps 500 kHz Ausgangsrückflußdämpfung / Output return loss > 14 dB Ausgangspegelbereich / Output level range 90 - 100 dBµV Einstellschritte / Step 1 dB Spektrale Inversion / Spectral inversion...
Seite 62
Technische Änderungen und Druckfehler vorbehalten! Empfangs- und Verteiltechnik Technical Modifications reserved. WISI cannot be held Wilhelm-Sihn-Straße 5-7, 75223 Niefern-Öschelbronn liable for any printing error. Tel . 07233 / 66-292, Fax. 66-320, http://www.wisi.de ... a link to the future - 62 -...