Inhaltszusammenfassung für Wisi STREAMLINEOE 01EdgeQAM
Seite 1
Betriebsanleitung Getting started WISI STREAMLINE OE 01 xxxx EdgeQAM • Multi channel QAM processor for DVB over IP signals • UDP over IP protocol • PCR correction • NIT replacement • SNMPv2c network management • 1 Gigabit Ethernet input for 8 MPTS/QAM channels...
Sicherheitshinweise - bitte beachten! Safety and installation notes – please observe! Achtung Caution Die angegebene Betriebsspannung 180-265 VAC; The operating voltage must match the rated input 50/60 Hz muß mit der Netzspannung übereinstimmen. voltage of the unit (180-265 VAC; 50/60 Hz). Anschlußkabel —...
Anschlüsse / Connectors LED - Power ON für Kanal 1...4 LED - Power ON for Channel 1...4 LED - Error für Kanal 1...4 LED - Error for Channel 1...4 Testbuchse -20 dB Test socket -20 dB Netzanschluß Mains plug Sicherung T2A/250 V Fuse T2A/250 V Netzschalter Mains switch...
Software - Gerät im Netzwerk suchen Den Button „Netzwerk durchsuchen“ anklicken - ein neues Fenster öffnet sich (Bild 1) Den Optionsbutton „Broadcast“ auswählen. Anschließend den Button „Suchen“ anklicken. (Bild 2) Jetzt sollten die im Netz verfügbaren OE 01 angezeigt werden. (Bild 3) Das gewünschte Gerät per klicken auswählen und die Verwendung bestätigen.
Seite 7
Software - IP-Adresse ändern Den Button „IP-Adresse ändern“ anklicken - ein neues Fenster öffnet sich (Bild 1) MAC-Adresse des gewünschten Geräts auswählen (Bild 2). Die neue IP-Adresse eingeben (Bild 3). Gegebenenfalls die neue Netz-Maske eingeben (Bild 3). Gegebenenfalls das neue Gateway eingeben (Bild 3). Auf „Ändern“...
Software - Einstellungen Kommunikation Verbindung IP-Adresse IP-Adresse des Geräts eingeben Read Community public Write Community private Automatisch Verbinden Ein / Aus Max. Anzahl OIDs SNMP Manager Trap-Empfänger aktiviert Ein /Aus Änderungen werden gespei- chert, Fenster wird geschlossen Abbrechen Eingaben werden verworfen und Fenster wird geschlossen Übernehmen Änderungen werden gespei-...
Software - Einstellungen Allgemein Sprachen German, English Detallierte Fehleranzeige Ballon Hints anzeigen Ein / Aus Anzeigedauer (ms) 2000 Schliessen Anwendung Beeenden Auslesen Gerätedaten auslesen Speichern Änderungen speichern - 9 -...
Seite 10
Software - Allgemein Netzmaske Anzeige Netzmaske Produktdaten Gateway IP-Adresse Gateway einstellen Artikelnummer Geräte Artikelnummer Seriennummer Geräte-Sereinnummer Zeit-Einstellungen Hardware Revision Stand der Hardware Datum/Uhrzeit Aktuelles Datum / Uhrzeit Firmware Version Stand der Firmware SNTP Server IP-Adresse SNTP-Server Zeitzone Einstellung der Zeitzone Temperatur Intere Temperatur (°C) Temperatrur im Gerät...
Software - Eingang 1...4 Kanal 1...4 Filter Quell IP Ein / Aus, Quell IP Filter einstellen Filter Quell Port Ein / Aus, Quell Port Filter einstellen Filter Ziel IP Ein / Aus, Ziel IP Filter einstellen Filter Ziel Port Ein / Aus, Ziel Port Filter einstellen NIT Anpassung Ein / Aus...
Software - Eingang 5...8 Kanal 5...8 Filter Quell IP Ein / Aus, Quell IP Filter einstellen Filter Quell Port Ein / Aus, Quell Port Filter einstellen Filter Ziel IP Ein / Aus, Ziel IP Filter einstellen Filter Ziel Port Ein / Aus, Ziel Port Filter einstellen NIT Anpassung Ein / Aus...
Software - Ausgang 1...8 Kanal 1...8 Kanal 5...8 Symbolrate (kSym/s) 4480 - 7000 Kanalraster (kHz) 5000 - 8000 Standard ITU-T J.83 Annex A, ITU-T J.83 HF-Pegel (dBµV)* 1 Kanal aktiv 84-104 dBµV Annex B, ITU-T J.83 Annex C 2 Kanäle aktiv 84-101 dBµV Kanal 1...4 4 Kanäle aktiv...
Seite 15
Software - NIT NIT Austausch Anpassung aktiv Ein / Aus NIT PID NIT PID eingeben Filter Quell IP Ein / Aus, Quell IP Filter einstellen Filter Quell Port Ein / Aus, Quell Port Filter einstellen Filter Ziel IP Ein / Aus, Ziel IP Filter einstellen Filter Ziel Port Ein / Aus, Ziel Port Filter einstellen...
Software - Graphical user interface Operating gents Close application Connect Search network Change IP adress n.n. General settings Software information - 19 -...
Seite 20
Software - Search network Click „Search network“button - a new window opens (Fig. 1) Select option „Broadcast“, then click the „Search“ button (Fig. 2). Now the OE01 available in the network should be visible (Fig. 3) To select the requested device click the respective IP adress and confirm the selection (Fig.
Seite 21
Software - Change IP adress Click the „Change IP adress“ button - a new window opens (Fig. 1) Select the MAC adress of the requested device (Fig. 2). Set the new IP adress (Fig. 3). If necessary change the Net-Mask (Fig. 3). If necessary change the Gateway (Fig.
Software - Settings communication Connection IP-Adress Set IP-Adress of the device Read Community public Write Community private Auto connect on / off OIDs count SNMP Manager Trap-Receiver active on / off Changes are saved, the window closes Abort Changes are discarded, the window closes Apply Changes are saved,...
Software - Settings general Languages German, English Detailed Error Description Show Balloon-Hints on / off Duration (ms) 2000 Changes are saved, the window closes Abort Changes are discarded, the window closes Apply Changes are saved, the window stays open - 23 -...
Seite 24
Software - general Netmask Indication of Netmask Product Date Gateway Set Gateway IP Adress Device Type Device Type Serial Number Device Serial number Time Settings Hardware Revision Hardware Version Date/Time actual Date and Time Firmware Version Firmware Version SNTP Server Set SNTP-Server IP Adress Time Zone Set Time Zone...
Seite 25
Software - Input 1...4 Channel 1...4 Filter Source IP on / off, set Source IP Filter Filter Source Port on / off, set Source Port Filter Filter Destination IP on / off, set Destination IP Filter Filter Destination Port on / off, set Destination Port NIT Replacement on / off Jitter Tolerance (ms)
Seite 26
Software - Input 5...8 Channel 5...8 Filter Source IP on / off, set Source IP Filter Filter Source Port on / off, set Source Port Filter Filter Destination IP on / off, set Destination IP Filter Filter Destination Port on / off, set Destination Port NIT Replacement on / off Jitter Tolerance (ms)
Seite 27
Software - Output HF Output Output active on / off RF Level Total (dBµV) Indication of RF Level Total RF Alarm enabled enabled / disabled RF Alarm Level Threshold Set RF Alram Level Threshold Frequency Allocation Zoom in Zoom out Close Closes the application Reload...
Seite 28
Software - Output 1...8 Channel 1...8 Channel 5...8 Symbolrate (kSym/s) 4480 - 7000 Channelspacing (kHz) 5000 - 8000 Standard ITU-T J.83 Annex A, ITU-T J.83 1 Channel active 84-104 dBµV RF Level (dBµV)* Annex B, ITU-T J.83 Annex C 2 Channel active 84-101 dBµV Channel 1...4 4 Channel active 84-98 dBµV Channelspacing (kHz)
Seite 29
Software - NIT NIT Replacement Replacement active on / off NIT PID set NIT PID Filter Source IP on / off, set Source IP Filter Filter Source Port on / off, set Source Port Filter Filter Destination IP on / off, set Destination IP Filter Filter Destination Port on / off, set Destination Port Filter...
Software - Status Channel 1...4 Channel 1...4 Status* Indication of Channel Status IP Input Signal Indication of IP input signal status Indication of PCR status Input Datarate (Sym./s) Indication of input datarate Datarate changes Number of datarate changes Max. Jitter (µs) Indication of max.
Software - Status Channel 5...8 Channel 5...8 Status* Indication of Channel Status IP Input Signal Indication of IP input signal status Indication of PCR status Input Datarate (Sym./s) Indication of input datarate Datarate changes Number of datarate changes Max. Jitter (µs) Indication of max.
Software - Log Status logs with time code Clear Clears the displayed Log data Close Closes the application Reload Reloads the device data Save Saves the changes - 32 -...
Technische Daten/Specifications Input Gigabit Ethernet 1000 BaseT Protocol MPEG over UDP/IP ARP, ICMP IGMP V2 (V3 prepared) IP adress unicast same port for different channels is not possible IP adress Multicast same IP address and same port for different channels is not possible IP jitter removal up to 100 ms TS format...
Blockschaltbild/Block diagram OE 01 3200 RF out GBE1 GBE2 GBE3 GBE4 Splitter Power supply RF-Combiner IP-QAM IP-QAM IP-QAM IP-QAM Transmodulator Transmodulator Transmodulator Transmodulator RF -20 dB - 35 -...
Seite 40
WISI Commmunications GmbH & Co. KG Empfangs- und Verteiltechnik Wilhelm-Sihn-Straße 5-7 75223 Niefern-Oeschelbronn, GERMANY Tel.: 07233 / 66-292, Fax.: 66-320, http://www.wisi.de Technische Änderungen und Druckfehler vorbehalten! Technical Modifications reserved. WISI cannot be held liable for any printing error. excellence in digital ...