- The float valve can respond prematurely when larger quantities
of fluid are sucked up. Turn off the appliance, remove the filter
and empty out the water.
- The filter can be dispensed with when liquid is primarily sucked
up.
- A second (exchangeable) filter should be used for frequent
changeover between dry and wet suction cleaning.
- When taking up strongly contaminated water, we recommend
the use of a washable foam filter instead of the folded filter
which has been fitted. If the foam filter is not part of the scope
of delivery, this filter can be ordered under the accessory article
no. 41 32 97.
8.3 Emptying the container.
Turn off ②a, disconnect the plug ④, and open the lock-in closure
⑭. Remove the top section ① and hose from the container w.
Empty the container or remove the paper filter bag ⑱ from the
suction opening.
9 Cleaning
From time to time the filter sack should be brushed or beaten.
Folded filters should be cleaned with a soft brush or, possibly, with
water. Dry the filter and container thoroughly so that dust cannot
adhere to moist parts. To prevent dirt accumulation and encrustati-
on, dry dust must be removed before changing over to wet suction
cleaning. Clean the container and accessories with water. Wipe the
top section ① with a moist cloth.
Check the function of the float valve, clean regularly and always
inspect for signs of damage. (Turn the top section around and see
that the float closes properly.)
9.1 Service
Note: Switch the vacuum cleaner off and pull out the mains plug
before any maintenance work.
For maintenance by the user, the vacuum cleaner must be
- dismantled,
- cleaned and
- maintained,
as far as possible without creating any danger to the maintenance
personnel or other.
Precautionary measures
Suitable precautionary measures include
- Cleaning before dismantling,
- Provide local filtered positive ventilation where the vacuum
cleaner is to be dismantled,
- Clean the maintenance area and
- suitable personal protection equipment.
Technical testing
A technical examination must be carried out at least once a year
by a trained person: check the filter for damage, ensure that the
Original operatin instructions in German
vacuum cleaner is air-tight and check that the monitoring equip-
ment functions correctly.
10 Transport VCF20/1000
To transport safety lay the hose round the cleaner and tuck under
the handle (Fig. K, Fig. M).
Insert the connecting cable for the mains lead into the top (Fig. L).
Place the suction hose and the nozzles into the accessory compart-
ment* or on to the suction hose holder* ⑳ (Fig. K).
11 Remedying faults
Functional faults are not necessarily always due a defective
appliance.
Fault:
Decreasing suction force:
Appliance does not start:
No other "interventions" are allowed; consult the servicing work-
shop (see enclosed sheet "Customer Service Workshops").
12 Technical data.
Appliance
Voltage
version
VCF20/1000. 220 - 240 V~
VCF32/1200
220 - 240 V~
VCF45/1400
220 - 240 V~
Appliance
Rated capacity
version
VCF20/1000.
1000 W
VCF32/1200
1000 W
VCF45/1400
1200 W
Possible Cause/Remedy:
Clogged filter – Clean.
Paper filter is full – Change
Container is full – Empty.
Clogged motor protection filter
– Clean.
Clogged nozzle, tube or hose
– Clean.
Is the plug insertes in the socket?
Mains failure?
ken?
Is the power supply cable bro
Frequency
Weight
50/60 Hz
6 kg
50/60 Hz
10 kg
50/60 Hz
14 kg
Maximum
capacity
1200 W
1400 W
1400 W
GB - 11