Boost function

Charging procedure in case of power failure
1.
When a mode for rechargeable lead batteries was selected before the power failure, the same mode is activated after the power failure.
2.
Boost function and calcium modes require a confirmation within 10 seconds after mains voltage is applied again. Without confirmation, the device
switches to summer mode for rechargeable lead batteries for safety reasons.
3.
If the power supply mode was selected before the power failure, the device indicates an error (also by signal sound). To reactivate this function, the
device must be confirmed by pressing the 'SET' and 'MODE' buttons simultaneously.
CLEANING
Before cleaning the device, disconnect it from the rechargeable battery and mains voltage.
Clean the outside of the product with a clean, dry, soft cloth.
Never use aggressive detergents, they might damage the housing.

TECHNICAL SPECIFICATIONS

Operating voltage: ............... 220 – 240 V AC/50/60 Hz
End-of-charging voltage: ...... 14.4 V ± 0.25 V or 14.7 V ± 0.25 V (rechargeable lead batteries)
.............................................. 16.0 V ± 0.25 V or 16.2 V ± 0.25 V (rechargeable calcium batteries)
....................................... 13.6 V ± 0.25 V (MAINTENANCE mode)
Charging current:
10 A ±10% or 5 A ±10%
Rechargeable battery type: .. 12 V rechargeable lead-acid batteries (open rechargeable batteries, AGM, gel )
.............................................. 12 V rechargeable calcium batteries
Capacity of battery: ............... 20 – 300 Ah (lead)
.............................................. 25 - 100 Ah (Calcium)
Safety class: ......................... IP65 (only the housing)
Dimensions: .......................... 245 x 60 x 100 mm
Weight: .................................. 950 g
Environmental protection note
At the end of its useful life, this product must not be disposed of together with normal household waste, but has to be dropped off at a collection
centre for the recycling of electrical and electronic devices. This is indicated by the symbol on the product, on the instruction manual or on the
packaging. The materials of which this product is made are recyclable pursuant to their labelling. With the reuse, the recycling of the materials or
other forms of scrap usage you are making an important contribution to the protection of the environment. Please ask your local administration
office for the appropriate disposal centre.
Technical specifications subject to change. We assume no liability for typographical errors. V1_01/2013
Tel: 0049 (0) 9622-719910, fax: 0049 (0) 09622-7199120; e-mail: info@ivt-hirschau.de; Internet:
IVT Innovative Versorgungs-Technik GmbH, Dienhof 14, 92242 Hirschau
- 12 -
www.IVT-Hirschau.de

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis