EN
User Manual
s
eCUrity warning
The device was designed for safe usage but
in your own safety it is advised to read the
following prescriptions:
Never exceed the allowed maximum voltage
•
or current
Be very careful when working with voltage
•
higher than 25VAC RMS as it may cause
electric shock. Never use the device if any
parts or cover are missing or are improperly
placed.
inward thresholds
function
AC current
DC current
Frequency
t
eCHniCal desCription
9
8
6
7
1. Clamps with current sensor
2. LED lamp button
3. Rotating function switch
4. Data hold and backlight button
5. LCD display
6. Trigger
7. Nullifier button
8. Non-contact AC voltage detector light
indicator
9. Non-contact AC voltage detector
maximum inward
value
200A
±200A
1kHz
1
2
3
4
5
d
esCription
4 digit digital LCD display with white LED
•
backlight
Built-in non-contact AC voltage detector with
•
LED lamp
Frequency measurement (40Hz - 1kHz)
•
Automatic treshold setting, with automatic
•
turn off
0.7" (18mm) clamp size
•
C
HaraCteristiCs
4 digit (2400) Digital LCD /
display
with white backlight
polarity
(-) shows negative polarity
overload
"OL" shown on the display
indicator
dca nullifier
Single button nullifier
sampling time
appr. 1 sec
Battery
2 x 1.5V AAA battery
low battery
"
power
the screen
automatic turn
appr. 7 minutes
off
32°F-86°F (0°C-30°C) 90%
usage
RH 86°F-104°F (30°C-40°C)
conditions
75% RH 104°F-122°F
(40°C-50°C) 45% RH
storage
-14°F-140°F (-25°C-60°C);
conditions
<90% RH
may be used under 3000
altitude
m
Weight
(175g) with battery
dimensions
164 x 65 x 32mm
clamp size
18mm (0.7")
general
IEC61010 Cat. II. 600V
measuring range characteristics
dc current
Range
Resolution
200A
100mA
" icon displayed on
Accuracy
(% read value)
± (2,8% + 8 digit)