Siemens MICROMASTER 440 Kurzanleitung Seite 152

Vorschau ausblenden Andere Handbücher für MICROMASTER 440:
Inhaltsverzeichnis

Werbung

BI: Enable JOG right
CO/BO: Binary input values
P1055.C
r0722
DIN
r0722
BI: Enable JOG left
BI: Function of digital output
P1056.C
P0731 [3]
DOUT
(52:3)
BI: Enable MOP (UPcommand)
P1035.C
CO: Act. ADC after scal. [4000h]
ADC
r0755 [2]
BI: Enable MOP (DOWNcommand)
P1036.C
CI: DAC
P0771 [2]
DAC
(21:0)
BI: Fixed freq. selection Bit 0
P1020.C
CO/BO: BOP control word
r0019
BI: Fixed freq. selection Bit 1
BOP
r0019
P1021.C
CO: PZD from COM link (USS)
r2018 [8]
BI: Fixed freq. selection Bit 2
BO: CtrlWrd1 from COM link (USS)
P1022.C
r2036
USS
BO: CtrlWrd2 from COM link (USS)
BI: Fixed freq. selection Bit 3
(COM-link)
r2037
P1023.C
RS485
CI: PZD to BOP link (USS)
P2016 [8]
BI: Fixed PID setp. select Bit 0
(52:0)
P2220.C
CO: PZD from CB
r2050 [8]
BI: Fixed PID setp. select Bit 1
BO: Control word 1 from CB
P2221.C
r2090
CB
BO: Control word 2 from CB
(COM-link)
BI: Fixed PID setp. select Bit 2
r2091
P2222.C
CI: PZD to CB
P2051 [8]
(52:0)
BI: Fixed PID setp. select Bit 3
CO: PZD from BOP link (USS)
P2223.C
r2015 [8]
BO: CtrlWrd1 from BOP link (USS)
BI: Enable PIDMOP (UPcmd)
r2032
USS
P2235.C
AOP
BO: CtrlWrd2 from BOP link (USS)
(BOP-link)
r2033
RS232
BI: Enable PIDMOP (DOWNcmd)
CI: PZD to BOP link (USS)
P2236.C
P2016 [8]
(52:0)
1
2
Overview
Connecting the external and internal setpoints
(0:0)
JOG
(0:0)
CI: Additional setpoint
(19:13)
CO: Act. Output freq. of the MOP
CI: Additional setpoint scaling
r1050
MOP
(19:14)
BI: Disable additional setpoint
(0:0)
(0:0)
CO: Act. fixed frequency
r1024
CI: Main setpoint scaling
FF
(0:0)
CI: Main setpoint
(722:3)
(0:0)
(0:0)
CO: Act. fixed PID setpoint
FF
r2224
PID
(0:0)
(722:3)
(19:13)
CO: Output setpoint of PIDMOP
PID
r2250
MOP
(19:14)
3
4
P1075.C
D
(0:0)
P1076.C
W
(1:0)
CO/BO: Act. control word 1
P1074.C
CO/BO: Act. control word 2
(0:0)
0
1
+
+
P1071.C
W
(1:0)
P1070.C
D
(755:0)
SUM/JOG
JOG frequency right
selection
0.00 ... 650.00 [Hz]
P1058.D (5.00)
JOG frequency left
0.00 ... 650.00 [Hz]
AFM
P1059.D (5.00)
RFG
V/f
FOC
Imax contr.
.
BI: Inhibit neg. freq. setpoint
.
.
P1110.C
(0:0)
BI: Reverse
P1113.C
(722:1)
BI: RFG enable
P1140.C
(1:0)
.
.
.
5
6
12.03.2001
V1.1
CO/BO: Act. status word 1
r0052
r0052
CO/BO: Act. status word 2
r0053
r0053
r0054
r0054
r0055
r0055
.
.
.
BI: ON/OFF1
P0840.C
(722:0)
BI: ON/OFF1 reverse
P0842.C
(0:0)
BI: 1. OFF2
P0844.C
(1:0)
BI: 2. OFF2
P0845.C
(19:1)
Sequence
control
BI: 1. OFF3
P0848.C
(1:0)
BI: 2. OFF3
P0849.C
(1:0)
BI: Pulse enable
P0852.C
(1:0)
7
8
Function diagram
- 1200 -
MICROMASTER 440