Chapter 5.5.2.6 Select Signal For Output - testo RS 485 Bedienungsanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5 5 . . 5 5 . . 2 2 . . 4 4 H H y y s s t t e e r r e e s s i i s s f f o o r r A A l l a a r r m m 2 2
S S e e t t s s w w i i t t c c h h i i n n g g o o n n h h y y s s t t e e r r e e s s i i s s ∆ ∆ a a f f o o r r A A l l a a r r m m 2 2
Menu <–> Selection
Select digit
Set digit
press the
key to accept the selection
S S e e t t s s w w i i t t c c h h i i n n g g o o f f f f h h y y s s t t e e r r e e s s i i s s ∆ ∆ b b f f o o r r A A l l a a r r m m 2 2
Menu <–> Selection
Select digit
Set digit

Chapter 5.5.2.6 select signal for output 2

press key
to accept
5 5 . . 5 5 . . 2 2 . . 5 5 R R e e s s e e t t L L a a t t c c h h s s i i g g n n a a l l a a t t O O u u t t p p u u t t 2 2
Menu <–> Selection
Manual reset with red key
Alarm output can only be reset manually if
is selected.. If
played, then the alarm output can only be reset manually if the totalizer reset
parameter "rESEt" has been programmed for "no.rES" or "EL.rE" .
Electrical reset with MPI-Input
Alarm output can only be reset electrically, if
is selected as the function and is displayed.
If
is selected as the function and is displayed, then the alarm out-
put can only be reset electrically if the totalizer reset parameter
has been programmed as
N N o o t t e e : : The Display Hold funktion is off.
Both, manual and electrical reset
Alarm output can either be reset manually via the red key or via a reset pulse
on the MP input. If
then the alarm output can only be reset manually and/or electrically if the to-
press the
key
talizer reset parameter
to accept
N N o o t t e e : : The Display Hold function is off.
Page 24
or
,
is selected as the function and is dis-
or
,
a
.
is selected as the function and is displayed,
is programmed as
.
5 5 . . 5 5 . . 2 2 . . 6 6 S S e e l l e e c c t t s s i i g g n n a a l l f f o o r r m m f f o o r r o o u u t t p p u u t t 2 2
Menu <–> Selection
Positiv output signal
Output (Clamp 1 to 2) is a a c c t t i i v v a a t t e e d d , when the instantaneous
value > limit 1
Negativ output signal
Output (Clamp 1 to 2) is d d e e a a c c t t i i v v a a t t e e d d , when the instantaneous
press the
key to
value > limit 1.
accept
5 5 . . 6 6 M M I I N N / / M M A A X X v v a a l l u u e e a a c c q q u u i i s s i i t t i i o o n n
The maximum value may be captured, saved and consulted during operation
by pressing a key.
5 5 . . 6 6 . . 1 1 C C a a p p t t u u r r e e o o f f M M I I N N / / M M A A X X V V a a l l u u e e s s
Menu <–> Selection
Not monitored
Monitored and saved.
press the
key to accept the selection
5 5 . . 6 6 . . 1 1 . . 1 1 R R e e s s e e t t M M a a x x i i m m u u m m v v a a l l u u e e
Menu <–> Selection
not resettable
Resettable via the
The MAX value can only be cleared by pressing the red key. In addition
press the
key to
"MAX" must be selected as the display source (see page 29) In parameter
accept
set-up "r.MAX" must be programmed as "YES"
5 5 . . 6 6 . . 2 2 M M i i n n i i m m u u m m V V a a l l u u e e M M o o n n i i t t o o r r
Menu <–> Selection
Not monitored
Monitored and saved.
press the
key to accept the selection
Chapter 5.6.2 ,
25
key .
Chapter 5.7 ,
26
Page 25