Herunterladen Inhalt Inhalt Diese Seite drucken

HBM T22 Montageanleitung Seite 16

Vorschau ausblenden Andere Handbücher für T22:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

16
Nominal torque M
nom
for reference only
Effect of temperature per
10 K in nominal (rated)
temperature range
on the output signal,
related to the actual value
of the signal span
on the zero signal, related
to the nominal (rated)
sensitivity
Power supply
Nom. (rated) supply voltage
Current consumption in
measuring mode
Nominal (rated) power
consumption
Permissible residual ripple
Linearity error including
hysteresis, related to the
nominal (rated) sensitivity
Rel. standard deviation of
the repeatability per DIN
1319, related to the variation
of the output signal
Max. level control range
Voltage / Current output
General specifications
2)
EMC
Immunity from interference
(DIN EN 61326-1/EN61000-6)
Enclosure
HF line interference
150 kHz−80 MHz (AM)
ESD (electrostatic
discharge)
Enclosure
Electromagnet. field
80 MHz−1000 MHz (AM)
1400 MHz−2700 MHz
(AM)
Lines - connect. cable
Burst (fast transients)
Emission (EME)
(EN 61326 / EN 55011)
RFI voltage
(interference at DC mains
connection)
RFI field strength
(Electromag. field strength)
1)
Output signal range with a repeatable relationship between torque and output signal.
Test severity / criterion: Industrial environment, cable length v30 m. Application not outside buildings.
2)
HBM
N⋅m
5
ft-lb
3.75
%
%
V (DC)
A
W
mV
pp
%
%
1)
%
V
kV
kV
V/m
V/m
kV
10
20
50
100
7.5
15
37.5
75
"0.2
"0.5
11.5...30
< 0.2
< 2.4
200
v"0.3
v"0.1
v120
10 / A
Air 8 / A
Contact 4 / A
10 / A
3 / A
2 / A
Class B (150 kHz−30 MHz)
Class B (30 MHz−1000 MHz)
T22
200
500
1000
150
375
700
A2302-2.0 en/de

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis