8 Commissioning

Correct weighing only possible at „reference height"
(see fig. 1 and 2)
 Actuate repeatedly the drawbar handle (hand lever 1 downwards. fig.1) until the
reference height is reached. In the display appears
 If the pallet truck scale is not in reference height, the weight
value in the display appears flashing.
 Place the pallet truck scale into reference height, the display
does not more flash.
16
Fig. 1
Fig. 2
see fig.2.