Assembly Instructions
A
B
C
A
Stripping pliers
B
Kevlar scissors
C
Cleave tool
D
Microscope
300 mm
1.
Remove the outer jacket using
a stripping tool.
2.
Set the cutting depth of the
stripping tool so that the inner
cores cannot be damaged.
5.
Cut off the blind elements (gray)
and the support element (white)
with the diagonal cutter.
8.
Remove the loose core sleeve
with your hand.
6
a
b
c
D
a
Anti-kink sleeve
b
Union nut
c
Buffer and Kevlar clamp
d
Body of connector
e
Ferrule
f
Dust protection
3.
Pull off the outer jacket.
80 mm
1,0 mm
6.
Position the ø 1 mm opening of
the stripping pliers approxi-
mately 80 mm from the end of
the core.
9.
Cut back 5 mm of the Kevlar
with the Kevlar scissors leaving
5 mm.
d
e
f
a
b c
d
a
Fibre
b
Kevlar threads
c
Cores (black and orange)
d
Blind elements (gray)/
support element (white)
e
Fleece wrapping
f
Outer jacket
4.
Cut off the Kevlar yarn and
fleece wrapping with the Kevlar
scissors.
7.
Cut into the core jacket and pull
the jacket partly off without
skewing.
10. Push the anti-kink sleeve and
the union nut over the Fibre
and core sleeve.
b e
b
f