Verfügbare Sprachen

11. Push the buffer and Kevlar
clamp onto the Fibre as far as
the core sleeve.
12. Fold back the Kevlar yarn.
15. Screw the connector body and
union nut together.
18. Turn the "Clamp" wheel slightly
towards the "Lock" direction to
clamp the Fibre.
22. Check the assembled connec-
tor with the microscope.
23. Then place the dust protection
cap on the ferrule.
Note:
If you find that the edge breaks are on the increase, the cleave tool should be sent in for inspection. When used cor-
rectly, up to 2000 assemblies are possible.
If you need to return the tool, talk to your Siemens contact.
Assembly Instructions
A5E00308064
0,3 mm
13. Cut into the buffer directly at
the crimp ring with pliers open-
ing ø 0,3 mm and pull off the
buffer without skewing.
16. Turn the "clamp" wheel to
"Open" and the "Cleave" wheel
to the "0" setting.
19. Turn the "Cleave" wheel slowly
from setting "0" to setting "2".
The connector surface is OK. Slight
irregularities at the edge are of no
significance.
24. Clean a contaminated connec-
tor with lint-free cloths.
Assembly Instructions
14. Push the connector body with
the ferrule onto the Fibre.
17. Feed the Fibre into the cleave
tool and lock the connector.
The Fibre projects through the
clamp wheel.
20. Turn the "Clamp" wheel in the
direction of "Open" and remove
the Fibre remnant.
21. Unlock the connector and
remove it.
Greater irregularities in the broken
edges and irregular light distribution
indicate a damaged connector sur-
face.
25. Repeat the connector assem-
bly.