Auxiliary
keypad
Adjustments:
output
level
CALTONE:4O0Hz
O
Press
the
keys
O
and
ENTER
Factory sefiings
The
correctness
ofthe
output
level
setting
can
be
verified
as
follows:
The built-in
calibration
tone
generator
is
switched
on
when the
station
memory 00
is
accessed.
This
is
acknowledged
on
the
dis-
play
[1
1] by
the message
CAL TONE:
400
Hz
(the station
number
and program
identifica-
tion
of
the
last
active station are retained).
A
400
Hz
sine
wave signal
with
a
level
that
cor-
responds to
a
f
requency deviation
of
40
kHz
is
fed to
the AUDIO
OUTPUTS
[35]
(for
most
stations
the
maximum
volume is
achieved
with
this frequency deviation).
The
factory
settings for the
output
level
(maxi-
mum value) and station
level
(medium
value)
can
be reestablished at
any
time.
Repetitively
press
the
LEVEL
[21]
key
untilthe
message
RESTORE
NOMINAL?
appears
on
the display
[1
'1].
lf
you
now
press
the
STORE
[31]
key the
facto-
ry settings
will
be reestablished.