8. Operation

GB
8.1 ON/OFF switch (B4)
To switch on:
Press the ON/OFF switch (1)
To switch off:
Release the ON/OFF switch (1)
8.2 Locking button (B5)
You can lock the ON/OFF switch (1) using the
locking button (2) when the equipment is in
operation. To lock it, press the ON/OFF switch
and slide the locking button to the left or right.
To switch off the equipment briefly hold down
the ON/OFF switch.
8.3 Variable speed control
Infinitely variable speed control is possible with
the On/Off switch (1). The further you press the
switch, the higher the speed can achieve.

9. Replacing the power cable

If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
aftersales service or similarly trained personnel to
avoid danger.

10. Technical data

Mains voltage:
Power input:
Stroke speed:
Cutting depth, wood:
Cutting depth, iron:
Protection class:
Weight:
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745.
L
sound pressure level 92,2 dB(A)
pA
K
uncertainty 3 dB(A)
pA
L
WA
K
WA
Wear ear-muffs.
The impact of noise can cause damage to
hearing.
Total vibration values (vector sum of three
directions) determined in accordance with EN
60745.
Vibration emission value a
K uncertainty = 1,5 m/s
The vibration value changes according to the
area of application of the electric tool and
may exceed the specified value in exceptional
circumstances.

11. Cleaning and maintenance

Always pull out the mains power plug before
starting any cleaning work.
11.1 Cleaning
• Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible.
Wipe the equipment with a clean cloth or blow it
with compressed air at low pressure.
• We recommend that you clean the device
immediately each time you have finished using it.
230-240 V~ / 50 Hz
1050 W
• Clean the equipment regularly with a moist
-1
0 – 2500 min
cloth and some soft soap. Do not use cleaning
150 mm
agents or solvents; these could attack the plastic
5 mm
parts of the equipment. Ensure that no water can
II /
seep into the device.
3,37 kg
11.2 Carbon brushes
• In case of excessive sparking, have the carbon
brushes checked only by a qualified electrician.
Important! The carbon brushes should not be rep
laced by anyone but a qualified electrician.
14
sound power level 103,2 dB(A)
uncertainty 3 dB (A)
≤ 25,65 m/s
h
2