• All electrical installation work should be
carried out by a qualified electrician in ac-
cordance with IEE regulations.
• The appliance must be separable from the
mains with an appropriate multipole device
with an air break of at least 3 mm. Con-
cerning this point a protective device, line
switch, fuses etc can be installed.
• This appliance must be installed (electrical
installation), commissioned and serviced by
approved service technicians in accordance
with these instructions.
• The hand dryer may only be fitted on a
vertical wall which is temperature resistant
to at least 90 °C.
• The unit rating plate is to be noted. The stated
voltage must correspond to the mains voltage
• If the heating unit is installed in rooms with
a bath and/or a shower, the range of pro-
tection according to the I.E.E. Regulations- in
conformity with the information on the unit
rating plate - must be taken into account.
• The hand dryer is to be fitted in such a way
that it cannot be touched by anyone in the
bath or under the shower.
• Any maintenance to the hand dryer should
be carried out by a qualified electrician. The
power supply should be disconnected be-
fore removing the front cover. Only original
Stiebel Eltron parts should be used.

2.4 Installation

The hand dryer should only be mounted on
a solid wall.
To install the unit follow these instructions:
2.4.1 Removal of front cover
HTE 4 (see page 3)
a. Remove the mounting screws (4).
b. Pull down the locking bolt (7).
c. Remove the front cover (1).
HTE 5 (see page 4)
a. Remove the mounting screw (4).
b. Pull down the locking bolt (7).
c. Slide off the outer casing (1).

3. Environment and recycling

Recycling of obselete appliances
Appliances with this label must not be
disposed off with the general waste.
They must be collected separately and
disposed off according to local regulations.
4. Guarantee
For guarantees please refer to the pespec-
tive terms and conditions of supply for your
country.
2.4.2 Wall mounting
a. Transfer the four mounting points to the
wall using the drilling template and drill the
mounting holes. Note the length and posi-
tion of the power supply lead.
b. Draw the power supply lead through the cable
grommet (5) at the rear panel of the dryer.
c. Screw the appliance (2) to the wall.

2.4.3 Electrical Connection

The dryer is designed only for permanent
connection to 0 V – 40 V~ 60 Hz alter-
nating current.
Please observe the rating place!
The PVC-angle (8) piece fixed in the
metalcase of the HTE 5 provides insu-
lation for the electric connection.
The voltage shown on the rating plate must
agree with the supply voltage. Cable should be
correctly sized in accordance with the loading
of the appliance.
The electrical connection must be done strict-
ly according to the wiring diagram.
9
I.
10
The wiring diagrams on pages 3 and 30 are
not valid for the HTE - A !
The installation, electrical connection
and first operation of this appliance
should be carried out by a qualified installer.
II.
motor.
2.4.4 Mounting the front cover
HTE 4
III.
a. Hook the button of the front cover onto
the front of the casing, and push top of
front cover towards the wall.
b. Push the locking bult upwards to secure the
case.
c. Fix securing screws.
HTE 5
a. Push the outer casing over the body of the
unit until it touches the wall. Ensure that the
outer casing is square to the wall.
b. To lock the outer casing in position, lift the
casing slightly from the front, and push up
the locking bolt.
c. Fix securing screw.
2.5 Handing over
Hand over the operating and installation in-
structions to the user. Explain the functions of
the unit and ensure that the user pays particu-
lar attention to the safety instructions.
11
The company does not accept liability for
failure of any goods supplied which accor-
dance with the manufacturer's instructions.
The power supply cable must not
be located in the vicinity of the fan
The maximum lenght of the cable
must not exceed 20 cm.