Overuse safeguard
The built-in safeguard will switch the pump off in the event of overheating.
Remove the plug from the socket and allow the pump to cool down.
The pump must not be switched on after cooling unless it has been checked.
Check the following points:
Is sufficient water available?
Is the suction basket blocked?
Is there dirt in the pump housing (clean as set out in the instructions)?
Is the suction/pressure hose/pipe blocked for this or other, connected,
devices?
Has the pump cooled down enough?
Once the problem has been resolved, the pump can be switched on again by
re-inserting the plug into the socket.
Dismantling: (figure 6)
Follow the safety instructions.
Remove the plug from the socket.
Take the suction basket (2 – if present) out of the pump housing (3).
Remove the pump housing screws (2).
Take the pump housing (3) off the motor housing (8).
Take the rotor (5) out of the motor (8).
Pay attention to the o-ring (4).
Clean all parts with clean water and a soft sponge.
Replace broken/damaged parts.
Assembly: (figure 6)
Put the rotor (5) back into the motor (8).
Replace the o-ring (4) and check to ensure this is positioned properly.
Check to ensure that the rotor (5) can turn around.
Replace the pump housing (3) on the motor (8) and then secure evenly
using the pumping house screws (2).
Place the suction basket (1) back on the pump housing (3) if the suction
basket (1) is being used.
Once everything is assembled, the pump can be switched on again.
Maintenance
To ensure a long life and problem-free operation, we recommend that you
maintain and clean your pump regularly. Maintenance work can be carried out by
anyone with very little effort, see also assembly/dismantling.
Time intervals:
In the beginning, you can check that the pump is working properly every
day. Clean the pump as set out above.
The regularity with which you clean the pump depends on the extent to
which the water is contaminated.
Check during maintenance to see if there has been any wear and tear or if parts
are worn or damaged. Replace any parts that are worn or damaged. Check the
list of replacement parts for this purpose. Important: If you have hard water
in your area, it is useful to regularly clean the rotor (5) and the interior
of the motor (8).