Herunterladen Diese Seite drucken

Renkforce G-077 Bedienungsanleitung Seite 3

Pmr-funkgerät

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

G Operating instructions
PMR Radio Device „G-077"
Item no. 1359884
Intended use
The product is used for wireless oral communication between two or more radiotelephones of the
same standard.
It is operated with a replaceable LiIon battery, it is charged via USB.
Always observe the safety instructions and all other information included in these operating instruc-
tions. If you pass the product on to a third party, please pass on these operating instructions as well.
Any use other than as described above is not permitted and can damage the product. In addition,
it can lead to hazards such as short-circuiting, fire, etc.
This product complies with the applicable National and European requirements. All names of com-
panies and products are the trademarks of the respective owners. All rights reserved.
Package contents
• 2x PMR radio device
• 2x LiIon battery
• 2x USB charging cable
• 2x earphones with microphone
• 4x foam for earphones
• Operating instructions
Explanation of symbols
This symbol points to specific risks associated with handling, function or operation.
The arrow symbol indicates special tips and operating information.
Safety instructions
Damage due to not following these operating instructions will void the warranty! We
do not assume any liability for any resulting damage!
We do not assume any liability for material and personal damage caused by improper
use or non-compliance with the safety instructions. In such cases, the warranty will
be null and void.
• The unauthorised conversion and/or modification of the product is not permitted for
safety and approval reasons (CE). Never open/dismantle the product (except for the
procedure described in these operating instructions for inserting/changing the re-
chargeable batteries).
• Do not use this product in hospitals or medical institutions. The product might cause
interference with the function of life-support equipment. The same may also apply to
other areas.
• The product is not a toy and does not belong in the hands of children. The product
contains small parts, glass (display) and a battery.
• The product is not water-tight or waterproof and must not get damp or wet.
• Do not expose the product to extreme temperatures, direct intense sunlight, strong
vibrations, high humidity or strong mechanical stress. Protect the product from dust
and dirt.
• Do not use the product in rooms with adverse environmental conditions, where com-
bustible gases, vapours or dust are or may be present! There is a risk of explosion!
• The product can cause a loud and unpleasant buzzing tone in hearing aids.
• Do not leave packaging material carelessly lying around, since it could become a
dangerous plaything for children.
• Handle the product with care; it can be damaged by impacts, blows, or accidental
falls, even from a low height.
• If you have any questions that are not answered in these operating instructions,
please contact our technical department or another specialist.
Battery notes
• Keep rechargeable batteries out of the reach of children.
• Do not leave the batteries lying around in the open; there is a risk of them being swallowed by
children or domestic animals. If they are swallowed, consult a doctor immediately.
• Replace or recharge flat rechargeable batteries in good time since flat or old batteries can leak.
• If your skin comes into contact with leaking or damaged batteries, you may suffer burns. Thus
you should use suitable protective gloves.
• Liquids leaking from rechargeable batteries are very chemically aggressive. Objects or surfaces
coming into contact with these liquids could be considerably damaged. Thus, store batteries/
rechargeable batteries in a suitable location.
• Rechargeable batteries must not be short-circuited, opened or thrown into a fire. There is a risk
of explosion!
• Observe correct polarity (plus/+ and minus/-) when inserting the battery.
Indicators and controls
1
"SCAN" button
2
"POWER/MENU" button
3
Microphone
4
Antenna
5
"UP" button
6
Connector for headset and recharging the battery
7
"DOWN" button
8
"PTT" button
9
Loudspeaker
A
"CT" symbol: CTCSS sub channel 1 - 38
B
"DCS" symbol: DCS sub channel 39 - 99
C
"VOX" symbol: Voice-activated PTT mode
D
"SCRA" symbol: Voice scrambler
E
Symbol for sending signal
F
Symbol for reception signal
G
Bar indicator for volume setting
H
"SOS" symbol: Alarm call
I
Symbol for alarm function
J
Symbol for button lock
K
Indication for battery condition
L
Time display (12h mode, "PM" = afternoon)
M
Channel number display
N
"FM" symbol: VHF/FM radio
Getting started
a) Inserting the battery
Proceed as follows for the two radio devices delivered:
• Open the battery compartment on the rear of the PMR radio device. To do this, carefully bend the
holding clip of the battery compartment cover back a little and then remove the battery compart-
ment cover.
• Now, insert the Lilon battery included observing the correct polarity so that the battery contacts
touch the corresponding contacts in the PMR radio device.
• Close the battery compartment.
If the battery is not flat, short signal will sound when inserting it. Furthermore, a symbol
is shown in the display and the display light goes on for a few seconds.
• At first startup, the battery must always be charged first.
b) Charging battery
• If the battery is low, the PMR radio device shows the time in the display but it cannot be switched
on. If the battery is completely flat, nothing is shown in the display.
The PMR radio device sounds a warning signal during operation with low battery. Operation can
then be continued for a short time; afterwards, the PMR radio devices switches off.
Only connect the PMR radio device to a USB power supply for recharging when the
battery is inserted in the PMR radio device.
If the USB power supply is switched off (e.g. if the PMR radio device is connected to a
computer and you shut down the computer), disconnect the charging cable from the
PMR radio device first.
Otherwise, the PMR radio device could be damaged.
• To charge the battery, open the dust protection cap covering the connector (6) and connect
the PMR radio device with a USB socket e.g. of a USB power adapter or with a USB port of a
computer or a USB hub with its own power adapter.
The USB port should be able to supply a current of at least 500 mA.
• When charging it for the first time, leave the PMR radio device connected to the USB power
supply for 12 hours.
The charging duration of later charging processes is dependent on the condition of the battery.
With a completely empty rechargeable battery, the charging process can last up to 6 hours.
A symbol (K) at the bottom left of the display indicates the condition of the battery.
• When the charging process is completed, disconnect the connection between the PMR radio
device and USB socket. Close the dust protection cap again.
The USB socket is only used for recharging the PMR radio device and not for data
transfer. Thus, the operating system of a computer does not recognise new hardware.
c) Connecting the headset
Open the dust protection cap covering the connector (6) and completely insert the stereo plug of
the headset provided. When using the headset, the microphone and the loudspeaker in the PMR
radio device are deactivated automatically.
It is not possible to use the USB charging cable and the headset at the same time.