Installation measurements of buoyancy protection for container TUBUS:
A: Filling, e.g. excavation
B: Netting
C: Filling material
D: Max. ground water level
E: Slope angle
H eü
max H gw
without netting
Immersion depth
without netting
max H gw with
netting
Immersion depth
with netting
H pit
H eü: Height soil coverage
H gw: Height ground water resp. stratum water level, min. allowed distance to the ground
surface
H Trench: Necessary depth of the excavation
The above given data only applies if the assembly instructions for the
containers are followed exactly, especially concerning the filling material as
well as filling and compacting
Further versions and uses of the buoyancy protection are available by enquiry.
Technische Änderungen und Rechte vorbehalten. Keine Haftung für Druckfehler
Die Inhalte der technischen Dokumentation sind Bestandteil der Garantiebedingungen
The contents of the technical documentation are a component of the guarantee terms
Es sind bei Planung und Einbau die einschlägigen Normen und andere Regelwerke sowie die Unfallverhütungsvorschriften zu
Planning and installation regulations are to be followed, as well as the accident prevention regulations.
Auftriebsicherung / Buoyancy protection
250
350
450
950
850
750
500
700
900
550
550
550
900
1000
1100
1650
1750
1850
REWATEC GmbH Februar 2010
Technical changes and rights reserved. No liability for misprints
DOKK7302
F: Bedding of the filling material
G: Tank height
H: Pit height
I: Thickness of the bedding of the
netting with filling material
550
650
650
550
1100
1300
550
1200
1950
2050
beachten.
21.02.2010
850
1000
1200
350
250
0
1700
2000
2400
2250
2400
2600
7 / 8