Herunterladen Inhalt Inhalt Diese Seite drucken

Novy 896/4 Montageanleitung Und Bedienungsanleitung Seite 21

Vorschau ausblenden Andere Handbücher für 896/4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• If needed turn the light out withe a quarter turn
to take it out of its support.
• Turn the starter with a quarter turn to take it
out.
• Place the new starter in its support and turn
with a quarter turn.
• The starter is installed correctly when you here
a soft clicking sound.
• Place the remplacement lamp in the support
and turn this with a quarter turn until you here a
soft clicking sound.
• alle models have 2 starters from the type:
OSRAM St 111 / Novy reference 804-016
Back to the start initial position
• Tighten everything again to the initial position.
• IMPORTANT! When the glass panel (A) is
placed back, the glass panel has to be pushed
over the filterholder so its fixed (fig. 3.3).
• Place the greasse filter back in its support
• Install the cover plate, don't forget to slide de
adjustements clips over the plugs and tighten
the cover plate again.
• The unit is ready for installation.
Electrical connection
The hood is equipped with a electric flex with
standard plug and has to be connected with an
electric socket with grounding. When you install
you need to make sure that it is easy reachable.
The replacement of the electric flex has to be
done by an approved installer.
The amperage and the consumption are marked
on the information sticker in the inside of the
hood.
Dimensions: page 22
Electrical schedule: page 23-24-25
894-4 Gebruik NL-FR-DE-EN.indd 21
EN 21
25/02/14 10:58

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

894/4898/4895/4897/4899/4

Inhaltsverzeichnis