Settings And Display On The Heat Pump Manager; Pre-Configuration; Settings; Operating Data - Wpm Econ Sol Montage- Und Gebrauchsanweisung

Für solarfunktion
Verfügbare Sprachen

Verfügbare Sprachen

7
7

Settings and display on the heat pump manager

7.1

Pre-configuration




NOTE
The solar function only becomes active when a network connection is
established with the heat pump manager and the solar module
7.2

Settings





















7.3

Operating data



EN-6
Pre-configuration of all system components
for dynamic menu structuring
Should solar control be carried out by the heat
pump manager?
System-specific parameters
Level for setting solar control
Temperature difference between the collector
and the cylinder at which charging is activated
Maximum tank temperature
In areas with very hard water, it is advisable to
lower the cylinder temperature.
Before the stagnation temperature is reached,
the maximum cylinder temperature is raised by
5K in order to cool the collector through heat
loss in the cylinder and the pipes.
Advisable if the collector field is partially
shaded
Time between two flushing periods
Nominal volume flow in the collector circuit
Has monoethylene or propylene glycol been
added as an antifreeze?
Proportion of glycol in the solar collector fluid
(as a percentage)
Reset the current value for the totalled
quantities of thermal energy
Current errors from the solar function can be
reset here
Display of sensor values and operating data
The temperature of the collector sensor and solar cylinder sensor is
displayed. Arrows when cylinder charging is in progress
Setting range
Display
Yes
Solar module
No
recognised
Setting range
Display
1K
Solar internal
...6K...
30K
30 °C
Solar internal
...85 °C...
95 °C
Yes
Solar internal
No
Yes
Solar internal
No
10 min
Solar
...30 min...
pump kick
60 min
0 L/min
Solar internal
...
100 L/min
Monoethylene
Solar internal
Propylene
0 / 10 / 20 / 30
Solar internal
40 %
Yes
Solar internal
No
Yes
Solar internal
No
Display
Solar internal