Herunterladen Inhalt Inhalt Diese Seite drucken

Commissioning And Operation - NovoPress ACO202 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für ACO202:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Feature of the press device when the battery is empty:
When a pressing operation begins, a check is made to determine whether the battery charge is
sufficient to complete the pressing operation. If this is not the case the device does not start.
The green LED flashes.
If the green LED flashes following a pressing operation, the pressing operation was carried out
correctly. The battery must be recharged prior to the next pressing operation.
7

Commissioning and operation

7.1
Preparing the ACO202 / ECO202
CAUTION!
Fingers risk being crushed if the device is operated without a press
jaw/adaptor jaw (Fig. 4).
If no press jaw/adaptor jaw is fitted, fingers could be placed in the at-risk zone.
Fingers could be crushed when the device is started.
Therefore:
– Do not operate the device without press jaws.
– Keep your fingers away from the at-risk zone.
Information!
The device will not start if the retaining pin (5) is incorrectly inserted. The green LED
flashes.
Information!
The press device is not suitable for continuous operation. Following 30
minutes of continuous operation, a short break of at least 15 minutes
must be taken to allow the device to cool down.
• Insert the press jaw/adaptor jaw into the press device as shown in Fig. 5 to 7.
19
ACO202/ECO202
EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Eco202

Inhaltsverzeichnis