Commissioning
• Install the pump on a level and solid surface.
• Install the suction lines so that these are ready for operation.
• Connect the device to the electricity.
• Fill the pump with water at the pressure connection.
• During suctioning, open the shut-off elements (spray nozzles, valves, etc.) completely so
that the air trapped in the suction pipe can escape.
• Depending on the suction height and air volume, the first suction process may take
approx. 0.5 min - 5 min. With longer suction zones, water should be refilled.
• If the pump is removed again after use, it must be filled with water again under all
circumstances prior to connecting and commissioning it again.

Maintenance instructions

• The pump is largely maintenance free. To ensure a long service life, however, we
recommend regular checking and maintenance. Attention! Prior to any maintenance
work, the pump must be disconnected from the mains; for this purpose, pull the power
plug of the pump from the outlet.
• Prior to longer periods of inactiveness or during the winter, the pump is to be rinsed
thoroughly with water, drained completely and stored in a dry place.
• In case of pending frost, the water pump must be drained completely.
• After longer periods of non-use, check whether the rotor still turns effortlessly by
briefly switching the pump on and off again.
• In case of possible clogging of the pump, connect the pressure line to the water pipe
and take the suction hose off. Open the water pipe. Switch the pump on repeatedly for
approx. two seconds. In most cases, this method clears any clogging.
Replacing the mains power line
Attention! Disconnect the device from the mains! A defect mains power line may
only be exchanged by an electrician.