Error causes and their correction.
The device is designed for industrial requirements. In the event of an error occurring in the
system, only in the most exceptional circumstances will the cause of the error lie with the
control unit itself.
Depending on the configuration and version of the control unit, the following errors are
recognised:
Display
Error
No fill level reading
No calibration
possible
No calibration
possible

Technical data

Measuring principle:
The measuring principle is based on the
different dielectric constants of water and air.
This effect leads to a corresponding change in
capacity between the strands of the measuring
cable proportional to the column of water.
The signal is then fed into a microprocessor
for the purposes of further processing and
evaluation. The control unit is designed for
the standardised measuring range of 4 mA to
20 mA.
Other measuring methods (e.g. pressure
measuring) instead of capacity measuring are
also possible with this device.
Subject to changes in the sense of further technical development.
Cause
- Cable torn or snapped
- Sensor not plugged in
- Sensor connected with
polarity the wrong way
round
- Fill level too high
- Container too small
- Fill level too low
VRC-6A2 control unit
Dimensions: 120 x 80 x 55 mm (WxHxD)
Operating voltage: 9V DC
Current consumption (operational): approx.
20mA
Weight: approx. 250 g, protection class: IP 54
Continuous display switching option (only
recommended when using an adaptor) using
an internal jumper.
VCS-2 2m / 15m sensor unit
Minimum container height: 60 cm
Dimensions: 31 x 53 x 14 mm (WxHxD),
Protection rating: IP 68
Length of measuring cable (depending on
version) 2,200 to 4,200 mm 2-wire, PE
insulation.
Connecting cable: coax, outer sheath PE
(available in various lengths)
Polarity: "+" = inner conductor, "-" =
shielding. Standard cable length 15 m.
Plug: F-Sat
Remedial action
- check sensor connection
- drain some water off
- select a larger container
• Fill up with water