Attaching capacitive sensor in cistern
Protective tube
Fasten wall
mounting with
stainless-steel
screw!
Marking
Cistern

Connector assembly

Strip off
5.0mm
A potentiometer (pot) is located
behind this hole filled with a special
grease (silicon grease). The upper
marking cay be electrically
moved using a 2.5mm screwdriver.
This pot may only be adjusted in
the most extremely justified
circumstances:
1. If the indicators less than 100%
when the container is full, or
2. If the indicator displays 100%,
but the container is not full!
Overflow
Warning!
When calibrating,
weight must be at
least 10cm below water
level! (residual water)
Weigh
Insert 30mm
copper pin
Fold back
shield,
cut off
Connecting cable
to control unit
Ø3.0 mm hole
Upper marking
(overflow level)
Plastic labyrinth
(thread through 2 holes only!)
Screw F plug
into position
14 / 36