Status Messages
Warming Up
Antari F-4
Ready To Faze
Warning!
Heater Overheat
Warning!
Temp Error
Technical Specifications
Input voltage
Fuse
Power Consumption
Warm-up time
Max. operating time
Fluid tank capacity
Fluid consumption
Compatible fluid
Control option
DMX channels
Power connection
DMX data connection
Dimensions
Dry weight
Machine heating up
Machine ready for operation
Machine has detected overheat on heater unit and will not
operate, please contact local distributor/dealer for service and
support.
Machine can not heat up and will not operate. Please contact
local distributor/dealer for service and support.
110-120V 60Hz
220-240V 50Hz
110 – 120V = 15A 250V
220 – 240V = 7A 250V
AC 120V/230V, 1500W
60 Sec. (approx.)
10 hrs max. output
5 L
7 ml/min.
Antari FLG water-based fluid
DMX 512, Manual, Adjustable haze volume and fan speed
2 channels, haze volume and fan speed
Power Cord
3-pin and 5-pin XLR
L 554 x W 274 x H 464 m
20.3 kg
10