If you do not want to programme any more programmes, you can leave
programming mode by pressing on the 'Zeit' button.
5.1 Switching on and off – At the same time every day:
Assuming that the LightBoy Digi Timer VTE is in programming
mode, press the 'Tag' button until ALL of the days of the week are
displayed simultaneously.
5.2 Switching on and off – On specifi c combinations of days
Assuming that the LightBoy Digi Timer VTE is in programming
mode, press the 'Tag' button until the relevant display appears:
A display of (MO / TU / WE / TH / FR)
A display of (SA / SU)
A display of (MO / TU / WE / TH / FR / SA) = Monday to Saturday
5.3 Changing programmed switching times
Move to the programme that needs to be changed by pressing repeatedly
on the 'Prog.' button. You then make the change by simply overwriting
the previous setting (see Programming the timer).
5.4 Deleting a switching command
Press the 'Prog.' button until the display shows the programme you want
to delete (1-7) and the word 'ON'.
Press the 'Std.' button until instead of the numeric hour display two
dashes appear (this comes after 23:).
Press the 'Min.' button until instead of the numeric minute display two
dashes appear (this comes after :59).
Press the 'Prog.' button and 'OFF' appears on the display.
Repeat the steps as above to delete Std. and Min. until two dashes
appear in each instance.
= Monday to Friday
= Saturday and Sunday
6. Switching on manually
By pressing the
button at any time, the next switching command is
brought forward and executed. All of the programming is retained in full.
The manual switch only works if and when the current time is being
shown on the display.
7. Important information
It can be helpful to make a note of the programme settings in order to
avoid any mix-ups when making programming changes.
Multiple consumer units can be connected to the timer, up to the
maximum load.
Protect the timer from heat, moisture, cold and direct sunlight.
In the event of a power failure, all connected consumer units are
switched off.
The power reserve supplies the timer with electricity so that the clock
continues to run and the switching programme remains saved.
8. Technical data
Mains connection
230 V ~, 50 Hz
Switching capacity
max. 16 (2.0) A / max. 3500 W
2A for inductive loads (e.g. motors)
Memory cells
12 (6x in and 6x out)
Power reserve
c. 2 hours
Subject to technical modifi cations without notice.