1.7

Conversion Factors

The SI unit of pressure and vacuum is the pascal, symbol Pa. This is related to psi
(pounds per square inch) and bar as follows:
1 bar = 100,000 Pa
1 psi ≈ 6895 Pa
1.8

Technical Support

For assistance with operating this device, please contact Pico Technology at
www.picoauto.com
1.9

Specifications

Inlet
Pressure ranges
Connector
Output
Scaling
Offset (typical)
Connector
Performance
Accuracy
Response time (10%
to 90%)
Power supply
Type
Charging current
Charging connector
Ambient operating
temperature
Ambient storage
temperature
Environmental
protection
Weight
Dimensions
Compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
DO187-9
0 to 600 bar
0 to 60 MPa
0 to 8700 psi
M16 x 2 Minimess test port
1 V / 100 bar
1 V / 1450 psi
1 V / 10 MPa
Manual zeroing
BNC female
1% of scale
100 µs
Built-in LiPo battery, not user-serviceable
500 mA (max.) at 4.75 V to 5.25 V from USB charger cable
USB mini, fits cable TA081
60 °C (140 °F) max.
60 °C (140 °F) max.
Splash-resistant against water, gasoline, diesel and hydraulic fluids.
Not immersion-proof.
332 g (11.7 oz)
132 x 64 x 31 mm (5.2 x 2.5 x 1.2 in)
CE, FCC Part 15 class A
0 to 60 bar
0 to 6 MPa
0 to 870 psi
1 V / 10 bar
1 V / 145 psi
1 V / 1 MPa
User's Guide