3. Notes
• Take adequate care not to fold or bend the cables when using this product.
• Do not install equipment that generates strong magnetic waves in the vicinity of this
product.
• Use this product in an environment having an ambient temperature range of 0°C to
and that is not directly exposed to sunlight or heat sources.
• Install this product on top of non-magnetic materials. If installing on top of magnetic
materials, insert a non-magnetic layer having a thickness of at least 3 mm between the
product and magnetic materail.
• Avoid touching other scales or other parts of the scale with this product.
• Do not attempt to reinstall this product.
• Make sure that the external magnetic field does not exceed 0.5 mT.

4. Installation Procedure

Installation using parallel pins
Preparation
Make holes on the scale installation surface for inserting parallel pins so that positioning can
be performed.
Recommended diameter: Pin ø4
• The distance between the pins should be 200 mm or less. (Fig. 1)
• The parallelism of the holes with respect to the machine guide should be 50 µm or less.
(See the Installation Dimensional Diagram.)
Installation
1.
Leave the scale near the machine where it will be installed for one hour so that the scale
can adjust to the machine temperature.
2.
Use a clean cloth dipped in alcohol to wipe off any dirt, dust or oil from the installation
surface.
3.
Insert the parallel pins. (Fig. 1)
4.
Check the orientation of the scale. Position the scale so that the Magnescale marks on
the scale and head are facing in the same direction. (Fig. 2)
Parallel pin
Parallel pin
insertion
hole
200 mm or less
2
(E)
−0.004
, Hole ø4
−0.012
M: Machine guide
0.05
Scale installation
surface
Fig. 1
+0.012
.
-0
Magnescale marks
M
+
45°C
Fig. 2