Herunterladen Diese Seite drucken

AIRFORCE F102 60 TSL2 Montage- Und Gebrauchsanweisung Seite 18

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
GB
INSTRUCTION ON MOUNTING AND USE
Check also the drawings on the initial pages with the alphabetical
and numerical references in the explanatory text.
Closely follow the instructions in this manual. We cannot
accept liability for any faults, detriment or fire damage to the
appliance due to non-compliance with the manual's
instructions. Installation and electrical connections must be
executed by a qualified technician. You should affix the hood
to a wall of sufficient weight-bearing capacity, so not to one
made of plasterboard. Do not install it inside a cupboard.
Installation
The cooker hood must be placed at a minimum distance of 65
cm from the cooking plane for electric cookers and 75cm for
gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater
distance, this has to be taken into account.
Do not tile, grout or silicone this appliance to the wall. Surface
mounting only. Do not fix chimney flue to furniture or fly over
shelves unless the chimney flue can be easily removed, in
case maintenance is ever required.
Use
The cooker hood is provided with an upper air exit B for
discharging fumes externally for models including chimney
flue C ( Suction Version A- exhaust pipe not supplied).
If cooking fumes and vapours cannot be externally discharged,
the cooker hood can be used in the recirculating version
F: the installation of 1 active charcoal filter F allows the
recirculation of fumes and vapours through the upper grid G.
Electrical connection
Make sure that there is a power socket near the hood and
that the system has a 30 mA differential. The mains voltage
must be the same as that on the label inside the hood. The
hood has a 1250 mm power cable with or without plug: if it
does have a plug, connect the hood to an accessible
approved socket; or if it does not (connection direct to the
mains), fit an approved bipolar switch with a minimum
contact opening of no less than 3 mm (accessible). This
installation and electrical connection must be executed by a
qualified technician.
Operation
A
C
B
With the hood switched off, pressing any key will activate
the control panel in stand-by mode. The symbols are
backlit by a white light, allowing you view and select the
desired function.
Pressing one of the keys again will start the corresponding
function, and its symbol will light up. After all functions
have been switched off, the control panel will remain in
stand-by mode for around 30 seconds and then switch off
automatically.
A: Light ON/OFF key: press this touch sensor to switch
on or off the lights of the hood.
C: Motor ON/OFF key (4 speed): press this touch sensor
to switch on the hood extractor fan at the same speed as it
D
E
F
was when last switched off. Use the „D" and „B" keys to
vary the speed (power) of extraction.
B: Decrease extraction speed (power) key: press this
touch sensor to reduce the extraction speed of the hood.
D: Increase extraction speed (power) key: press this
touch sensor to increase the extraction speed of the hood.
E: Timer key: when this touch sensor is pressed,
independently of the extraction speed selected, the timer
function will be activated. Press once to set the timer for 5
minutes, press a second time for 10 minutes and a third
time for 20 minutes. During this phase, the „E" symbol will
flash.
To reset the timer, press the motor key, „C"
F: Reset filters key: press this touch sensor to reset the
signal that warns that the metal grease filter (1) is saturated
and the charcoal filter (2) should be replaced.
(1)
After 40 hours of using the hood, the „F"
symbol will flash to indicate the necessity of
cleaning the metal grease filters.
(2)
After 120 hours of using the hood, the „F"
symbol will light up to indicate the necessity of
replacing the activated charcoal filters.
Sensor function: pressing the „B" and „D" keys at the
same time will activate the sensor. In this mode the
extraction speed sets itself automatically and the „B+D"
key flashes intermittently. To return to manual operation,
press either the „B" or the „D" key.
Maintenance
Prior to any maintenance operation ensure that the cooker hood
is disconnected from the electrical outlet.
Cleaning:
The cooker hood should be cleaned regularly internally and
externally.For cleaning use a cloth moistened with denatured
alcohol or neutral liquid detergents. Avoid abrasive detergents.
Warning: Failure to carry out the basic standards of the cleaning
of the cooker hood and replacement of the filters may cause fire
risks. Therefore we recommend observing these instructions.
Anti-grease Filter – must be cleaned once a month, with non
abrasive detergents, by hand or in dishwasher on low temperature
and short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
Charcoal Filter - (only for filter version):
The active charcoal filters F are not washable nor regenerative.
It should be changed every 6 months in normal use.
The active charcoal filters capture unpleasant cooking odours.
Replacing lightbulbs
Warning! Prior to touching the light bulbs ensure they are cooled
down.
LED LIGHT
If the lighting group LED does not work, please contact the
technical service center in order to replace the whole group.
1 4

Werbung

loading