GB
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
This refrigerator is equipped with overheating
protection. An authorised service technician can
check whether this has been triggered or not.
In the event of a fault
nearest Service Centre-see local telephone directory.

14. Putting into operation

Technical data:
Model
RH 023 LDA
Type
MF20-60
Gross volume
23 litres
Mains operation
220-240V (AC)
Input
75W
Energy consumption
0,8 kWh/24h
Climate class
N
Refrigerant
159g H

14.1. Connecting to electrical mains

The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with
regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
rating plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted. In
the event of having to change the fuse in the plug
supplied, a 3 amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
for any reason, the wires in the mains lead are
coloured in accordance with the following code:
Green and Yellow:
Blue:
Brown:
The wire coloured green and yellow must be
connected to the terminal marked with the letter „E" or
by the earth symbol
The wire coloured blue must be connected to the
terminal „N" or coloured black.
The wire coloured brown must be connected to the
terminal marked „L" or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.
8
developing, contact your
RH 023 LDAG
MF20-60
23 litres
220-240V (AC)
75W
1,02 kWh/24h
N
O + 86g NH
159g H
O + 86g NH
2
3
2
Earth
Neutral
Live
or coloured green and yellow.