sPecificaTions

Valid at 23 degrees C after a 30 minute warm-up period
Measurements
10 kHz to 30 MHz
Frequency Range:
Impedance
Z = 50
Characteristics:
Error < 20% under terms of
VDE 0876T1
16 A
Max. Current:
230 V / 50 - 60 Hz, CAT II
Line Voltage:
220 pF + 511
Artificial Hand:
50
PE (switchable):
Transient Limiter
150 kHz to 30 MHz
Frequency Range:
Transmission Loss:
10 dB (+1,5/–0,5 dB)
connectors
50
Measurement Output:
Power Supply Socket
Standard German electr. socket
for DUT:
4 mm banana socket
Artificial Hand:
fixed
Power cable:
Miscellaneous
Operating temperature: +5°C . . . +40°C
Storage temperature: –20°C . . . +70°C
Max. relative humidity: 5% . . . 80%
(without condensation)
Power Supply:
230 V / 115 V, 50-60Hz

Safety:

Safety class I
(IEC 1010-01/VDE 0411)
285 x 125 x 380 mm
Dimensions (W x H x D):
approx. 6 kg
Weight:
Included in delivery:
HM6050-2, Manual
II(50µH + 5
)
II 50 µH
BNC
S p e c i f i c a t i o n s

Important hints

Used Symbols

(1)
(2)
(3)
Symbol 1:
ATTENTION refer to manual
Symbol 2:
DANGER High voltage
Symbol 3:
Protective ground (earth) terminal
Symbol 4:
Important note
Symbol 5:
Stop!
Possible instrument damage!
Symbol 6:
L1/N – identification of power lines
(Lit, if the power cable connector
is plugged in correctly (phase))

Unpacking

It is highly recommended to read this operating
manual before using the HM6050-2 . Please check
for completeness of parts while unpacking. Also
check for any mechanical damage or loose parts.
In case of transport damage inform the supplier
immediately and do not operate the instrument.

Transport

Please keep the carton in case the instrument
may require later shipment for repair. Losses and
damages during transport as a result of improper
packaging are excluded from warranty!

Storage

Dry indoor storage is required. After exposure to
extreme temperatures, wait 2 hr before turning
the instrument on.
Safety
The instrument conforms to VDE 0411/1 safety
standards applicable to measuring instruments
and it left the factory in proper condition according
to this standard. Hence it conforms also to the
European standard EN 61010-1 resp. to the inter-
national standard IEC 61010-1. Please observe all
warnings in this manual in order to preserve safety
and guarantee operation without any danger to the
operator. According to safety class 1 requirements
Subject to change without notice