Testing
The operation of the light curtain is to be tested as follows once it has been mounted.
1.
A test rod with a diameter of 50mm must be continuously detected over a range of
0mm to 500mm above the ground.
2.
A test object with an edge length of 200mm must be continuously detected over a
range of 0mm to 2500mm above the ground. The test bodies should be moved from
bottom to top during these tests.
Top view:
Door and recommended light curtain layout of T=transmitter and R=receiver
T
R
Without door function
(Blanking function)
R
T
Figure 1
Figure 2
With door function
(Blanking function)
www.flexiforce.com