Technical data
Safety parameters
Door widths
Rated voltage
Current consumption
Power consumption
Detection zone height
Channel count
Type of light
Type of switching:
Aperture angle
Detection capability
Door function
OSE output
PNP output
NPN output
SSR output
ESPE type 2 as per IEC 61496-2
MTTF
> 100 years; DC
D
(PFH=7.33 . 10
1/h) as per EN 61508-2;
-9
Category 2 for LIGI-xx-Nxx and LIGI-xx-Pxx with only one
suitable external control system for testing
1.6 to 10m
24V DC -58% +25% (10 to 30V DC)
Transmitter: Approx. 30mA (24V DC)
Receiver:
Approx. 20mA (24V DC)
Approx. 1.2W
Max. 2520mm
Max. 57
Modulated infrared
Light switching, i.e. the following applies for free detection zones:
OSE output = Alternating signal (approx. 950Hz)
PNP output = High level
NPN output = Low level
Approx. ±5°
0 to 500mm, detection object ≥ 50mm
500 to 2520mm, detection object ≥ beam separation
distance + 5mm
max. door speed:
(version A; bottom part > 100mm) 1,1m/s
(version A; bottom part > 125mm) 1,3m/s
(version C; bottom part > 370mm) 1,3m/s
Approx. 950Hz, alternating signal, 4V 20mA, short proof,
reverse polarity protection, max. 100nF, max. 30µA leakage current,
integrated pull-down 220Ω
100mA, short proof, reverse polarity protection, max. 220nF,
max. 350µA leakage current, integrated pull-down 10kΩ
100mA, short proof, reverse polarity protection, max. 220nF,
max. 150µA leakage current, integrated pull-up 10kΩ
100mA, short proof, max. 220nF, max. 30VDC, max. 21VAC
R on < 35kΩ, leakage current < 100µA
> 99% Category 2; PL d
AVG
www.flexiforce.com
manual – forceLC2
11