10 CLEANING AND MAINTENANCE
Attention! Before performing any work on the equipment, pull the power
plug.
10.1
Cleaning
▪
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
▪
Regularly clean the machine housing with a soft cloth, preferably after each use.
▪
Keep the ventilation slots free from dust and dirt.
▪
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
10.2
Lubrication
The machine does not require any specific lubrication.
11 TECHNICAL DATA
Voltage / frequency
Power input
No load speed
Max. disc diameter:
Drive spindle thread:
12 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
Acoustic power level LwA
ATTENTION!
over 85 dB(A).
aw (Vibration)
13 SERVICE DEPARTMENT
▪
Damaged switches must be replaced by our after-sales service department.
▪
If the connecting cable (or mains plug) is damaged, it must be replaced by a special
connecting cable which is available from our service department. Replacement of the
connecting cable should only be carried out by our service department (see last page) or
by a qualified specialist (qualified electrician).
14 STORAGE
Thoroughly clean the whole machine and its accessories.
▪
▪
Store it out of the reach of children, in a stable and secure position, in a cool and dry
place, avoid too high and too low temperatures.
▪
Protect it from exposure to direct sunlight. Keep it in the dark, if possible.
▪
Don't keep it in plastic bags to avoid humidity build-up.
Copyright © 2026 VARO
POWX0614
220-240 V / 50 Hz
1200 W
6000-12000 min-1
Ø 125 mm
M 14
87 dB(A)
98 dB(A)
Wear
hearing
6,2 m/s²
p a g e
protection
when
9
|
sound
pressure
K = 1,5 m/s²
www.varo.com
EN